Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
no
Type of method:
method to determine freezing temperature
Key result
Melting / freezing pt.:
-24 °C
Atm. press.:
101.2 kPa
Remarks on result:
other: Mean of 2 runs

Table 1. Measured temperature at regular intervals for both runs 1 and 2.

  Temperature (°C)
Time (min) Run 1 Run2
0 20.5 20.8
1 15 15.5
2 4.5 4
3 -3 -2.5
4 -12.8 -12
5 -20.5 -20
6 -24 -23.7
7 -24.3 -24
Freezing Temperature -24.3 -24
Average -24.2
Conclusions:
The freezing point of the test item was determined to be -24°C at 101.2 KPa.
Executive summary:

The freezing point of the test item was determined by using a freezing temperature method according to OECD TG 102. The freezing point was determined to be -24°C at 101.2 KPa. The melting point of the test item could not be determined at a temperature range of -170°C to 20°C by Different Scanning Calorimeter (DSC). There was no endothermic peak. The study is reliable with restrictions, being non-GLP compliant, but having followed a standard guideline.

Description of key information

The freezing point of the test item was determined to be -24°C (249 K) at atmospheric pressure. The melting point of the test item could not be determined at a temperature range from -170°C to 20°C by Differential Scanning Calorimetry.

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
-24 °C

Additional information

The freezing point of the test item was assessed by Differential Scanning Calorimetry conducted according to OECD TG 102 guideline. The study is a guideline, non-GLP, experimental study, acceptable for assessment of this endpoint (2013).