Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
not specified

Test material

Constituent 1
Chemical structure
Reference substance name:
2-hydroxybenzimidazole
EC Number:
210-412-4
EC Name:
2-hydroxybenzimidazole
Cas Number:
615-16-7
Molecular formula:
C7H6N2O
IUPAC Name:
2-hydroxybenzimidazole

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
> 255 s
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

The test item could be ignited with a flame. After 4 minutes and 15 seconds and a burning distance of about 40 mm the flame extinguished. The main test therefore was not necessary.

Applicant's summary and conclusion

Interpretation of results:
other: not highly flammable
Conclusions:
The test item is not a highly flammable solid in the sense of EC No. 440/2008; A.10