Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015 - 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
None
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Principles of method if other than guideline:
Guideline followed
GLP compliance:
no
Specific details on test material used for the study:
None

Safety Pre-Test

A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.

Preliminary screening test

The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes.

Interpretation of results:
GHS criteria not met
Conclusions:
The test substance was considered to be not highly flammable as it did not show ignition during the preliminary screening test.
Executive summary:
A study, according to EU Method A.10, was performed in order to determine the flammability of FAT 20063/D TE. A preliminary screening test was performed to determine if, on ignition by a gas flame, propagation by burning with flame or smoldering occurs. The test item was formed into an unbroken strip or powder train about 250 mm long. If propagation over 200 mm of the train occurs within a specified time, then a full test program to determine the burning rate was to be carried out. The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes. Hence the burning rate determination was not required. In summary, the test substance was considered to be not highly flammable as it did not show ignition during the preliminary screening test.

Description of key information

The test substance was considered to be not highly flammable as it did not show ignition during the preliminary screening test.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

A study, according to EU Method A.10, was performed in order to determine the flammability of FAT 20063/D TE. A preliminary screening test was performed to determine if, on ignition by a gas flame, propagation by burning with flame or smoldering occurs. The test item was formed into an unbroken strip or powder train about 250 mm long. If propagation over 200 mm of the train occurs within a specified time, then a full test program to determine the burning rate was to be carried out. The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes. Hence the burning rate determination was not required. In summary, the test substance was considered to be not highly flammable as it did not show ignition during the preliminary screening test.

Justification for classification or non-classification

As the substance was considered to be not highly flammable in a flammability study, it does not warrant classification according to CLP (Regulation 1272/2008) criteria.