Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Determination of the Granulometry of TKK 13332 using a procedure designed to be compatible with the European Commission Technical Guidance Document EUR 20268 ‘Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances’ (2002).

Additional information

Granulometry data acquired for the test item is:

Percentage of test item with an inhalable particle size <100 µm (sieve method): 56.5%

Percentage of test item with a thoracic particle size <10.0 µm (Cascade Impactor): 2.54%

Percentage of test item with a respirable particle size <5.5 µm (Cascade Impactor): 0.246%