Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Principles of method if other than guideline:
The granulometry, i.e. particle size, of the samples are determined by sieving and ultrasonic washing
GLP compliance:
no
Type of method:
sieving
Remarks:
The granulometry, i.e. particle size, of the samples are determined by sieving and ultrasonic washing.
Type of distribution:
volumetric distribution

Test material

Constituent 1
Reference substance name:
Precipitate from tellurium containing acid solutions by copper metal cementation
EC Number:
943-528-5
Cas Number:
2415991-19-2
Molecular formula:
not applicable (UVCB)
IUPAC Name:
Precipitate from tellurium containing acid solutions by copper metal cementation
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Particle size
Percentile:
D50
Mean:
>= 0.02 - <= 3.36 mm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
> 850 µm
Distribution:
ca. 13.5 %
No.:
#2
Size:
> 600 - <= 850 µm
Distribution:
ca. 11.32 %
No.:
#3
Size:
> 425 - <= 600 µm
Distribution:
ca. 5.96 %
No.:
#4
Size:
> 300 - <= 425 µm
Distribution:
ca. 4.82 %
No.:
#5
Size:
> 212 - <= 300 µm
Distribution:
ca. 5.64 %
No.:
#6
Size:
> 150 - <= 212 µm
Distribution:
ca. 8.21 %
No.:
#7
Size:
> 106 - <= 150 µm
Distribution:
ca. 6.97 %
No.:
#8
Size:
> 75 - <= 106 µm
Distribution:
ca. 5.04 %
No.:
#9
Size:
> 45 - <= 75 µm
Distribution:
ca. 5.36 %
No.:
#10
Size:
> 20 - <= 45 µm
Distribution:
ca. 4.22 %

Applicant's summary and conclusion

Conclusions:
The particle size distribution has been determined by sieving and ultrasonic washing. The results are detailed above.
Executive summary:

The particle size distribution has been determined by sieving and ultrasonic washing. The results are detailed above.