Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Justification for type of information:
Data is from study report
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Principles of method if other than guideline:
The flash point of a flammable liquid is the lowest temperature at which there will be enough flammable vapor to ignite when an ignition source is applied.
GLP compliance:
no
Type of method:
closed cup
Key result
Flash point:
94 °C
Atm. press.:
976 hPa
Remarks on result:
other: Other details not known
Interpretation of results:
other: Not flammable
Conclusions:
The flash point determination of test chemical was done following closed cup method using Pensky-Martens Flash Point Apparatus. The test was conducted in replicates and mean flash point was determined to be 94 °C at 976.0 hPa.
Executive summary:

The flash point determination of test chemical was done following closed cup method using Pensky-Martens Flash Point Apparatus. The test was conducted in replicates and mean flash point was determined to be 94 °C at 976.0 hPa.

Description of key information

The flash point determination of test chemical was done following closed cup method using Pensky-Martens Flash Point Apparatus. The test was conducted in replicates and mean flash point was determined to be 94 °C at 976.0 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
94 °C

Additional information

The flash point determination of test chemical was done following closed cup method using Pensky-Martens Flash Point Apparatus. The test was conducted in replicates and mean flash point was determined to be 94 °C at 976.0 hPa.

Based on the data obtained from the secondary source, the flash point of the test chemical was determined to be 107 °C.

Based on the data obtained from the reliable source, the flash point of the test chemical was determined to be >212 °F.

Thus, based on the above data, the flash point of test chemical ranges from 94 °C to 107 °C.