Registration Dossier

Environmental fate & pathways

Hydrolysis

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Hydrolysis testing was conducted in accordance with OECD Guideline 111.  The preliminary test showed that that the substance was hydrolytically stable at all pH levels and that a definitive test was not required. 

Key value for chemical safety assessment

Half-life for hydrolysis:
1 yr
at the temperature of:
25 °C

Additional information

A preliminary hydrolysis test was conducted in accordance with OECD Guideline 111. The substance was shown to be hydrolytically stable at pH levels of 4, 7 and 9, each conducted at a temperature of 50oC. A definitive test was not required. The hydrolysis half-life was determined to be greater than one year at all three pH levels.