Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From April 25, 2006 to April 26, 2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method
Media:
soil/sewage sludge
Radiolabelling:
no
Test temperature:
25°C
Details on study design: HPLC method:
- HPLC equipment: HPLC System Agilent 1100 series: HPLC pump G1311A, autosampler G1313A, column oven G1316A, degaser G1322A and UV/Vis detector G1314A by Agilent

- Column:
Stationary phase: LiChrospher 100 CN 5µm by Duratec (17405-02)
Material: stainless steel, dimensions: 250 mm x 4.6 mm
Column temperature: 25°C

- Mobile Phase: Methanol, cleaned water 50:50 % (v/v), isocratic elution
- Flow rate: 1.0 mL/minute
- Injection volume: 10 µL
- Detection wavelength: 210 nm for dead time marker, calibration substances and 420 nm for test substance
- Injection amounts/dilutions:
Dead time marker: 22.3 µg
Calibration substances: 0.68 - 1.79 µg
Test substance: 0.619 µg

- The dead time marker was dissolved in methanol and diluted 0.1 to 1 in the mobile phase and injected as single standards twice. The calibration substances were dissolved in methanol and diluted 0.1 to 1 in the mobile phase and injected as single standards twice. The test substance was dissolved in distilled water and diluted 0.1 to 1 with the mobile phase and injected as single sample twice.
- Reagents
Methanol, Chromasolv, Riedel de Haen
Cleaned water (laboratory equipment)
Distilled water, Roth
Dead time marker: Formamide, Merck
Calibration substances: Acetanilide, Atrazin, Monuron, Triadimenol, Linuron, Pyrazophos, Diclofop-methyl (Riedel de Haen)

Analytical monitoring:
not specified
Key result
Type:
log Koc
Value:
< 1.25
Temp.:
25 °C
Remarks on result:
other: log Koc of the test substance was below the log Koc of the lowest calibration substance (acetanilide)
Details on results (HPLC method):
- Dead Time (to) = 3.115 minutes
- Adsorption coefficient of the test substance (log Koc) <1.25
Transformation products:
not measured

Table 1: Determination of the Dead Time (to)

Dead time marker

tRin minutes

Measurement - 1

tRin minutes

Measurement - 2

tRin minutes

Measurement - 3

Formamide

3.116

3.114

3.115

 Dead Time (to) = 3.115 minutes

 

Table 2: Calibration Data - Measurement 1

(*from OECD guideline 121, adopted January 2001)

Calibration substance

1. Injection tRin minutes

k

log k

Log Koc*

Acetanilide

4.014

0.29

-0.54

1.25

Atrazin

4.514

0.45

-0.35

1.81

Monuron

4.743

0.52

-0.28

1.99

Triadimenol

5.511

0.77

-0.11

2.40

Linuron

6.230

1.00

0.00

2.59

Pyrazophos

8.919

1.86

0.27

3.65

Diclofop-methyl

10.833

2.48

0.39

4.20

Regression:Log Koc=a+bxlogk

Parameters:

a = 2.83

b = 3.07

r2= 0.9849

 

Table 3: Log Kocof the test substance - Measurement 1

Test substance

1. Injection tRin minutes

k

log k

Log Koc

Reaktiv Braun F05-0209-05

1.186

-0.62

<-0.54

<1.25#

#Below log Kocvalue of the lowest calibration substance (acetanilide).

 

Table4: Calibration Data - Measurement 2

(*from GECD guideline 121, adopted January 2001)

Calibration substance

1. Injection tRin minutes

k

log k

Log Koc*

Acetanilide

4.009

0.29

-0.54

1.25

Atrazin

4.510

0.45

-0.35

1.81

Monuron

4.742

0.52

-0.28

1.99

Triadimenol

5.514

0.77

-0.11

2.40

Linuron

6.229

1.00

0.00

2.59

Pyrazophos

8.917

1.86

0.27

3.65

Diclofop-methyl

10.825

2.48

0.39

4.20

Regression:Log Koc=a+bxlogk

Parameters:

a = 2.83

b = 3.07

r2= 0.9849

 

Table5: Log Kocof the test substance - Measurement 2

Test substance

2. Injection tRin minutes

k

log k

Log Koc

Reaktiv Braun F05-0209-05

1.183

-0.62

<-0.54

<1.25#

#Below log Kocvalue of the lowest calibration substance (acetanilide).

 

Table6: Log Koc of the test substance

Measurements

log Koc

1. Measurement

<1.25

2. Measurement

<1.25

Mean

<1.25

 

The adsorption coefficient (LogKoc) of the test substance was found to be <1.25

 

Validity criteria fulfilled:
yes
Conclusions:
Under the conditions of the study, the adsorption coefficient (i.e., log Koc) of the test substance was determined to be <1.25. The substance has expectedly no adsorptive properties in soil.

Executive summary:

A study was conducted to determine the adsorption coefficient of the test substance according to the "HPLC method" described in EU Method C.19 and OECD Guideline 121, in compliance with GLP.

The test substance was injected twice into an HPLC column where the stationary phase was composed of LiChrospher 100 CN (5 µm). Methanol/cleaned water (50:50 v/v) was used as the mobile phase. A calibration graph was drawn by measuring the retention times of a series of substances with known adsorption coefficients. The adsorption coefficient of the test substance was derived by comparing its retention time with the calibration curve. Detection of the test substance was carried out at 420 nm.

 

Under the conditions of the study, the adsorption coefficient (i.e., log Koc) of the test substance was determined to be <1.25

Description of key information

The adsorption coefficient (i.e., log Koc) of the test substance was determined to be <1.25.

Key value for chemical safety assessment

Koc at 20 °C:
17.8

Additional information

A study was conducted to determine the adsorption coefficient of the test substance according to the "HPLC method" described in EU Method C.19 and OECD Guideline 121, in compliance with GLP. The test substance was injected twice into an HPLC column where the stationary phase was composed of LiChrospher 100 CN (5 µm). Methanol/cleaned water (50:50 v/v) was used as the mobile phase. A calibration graph was drawn by measuring the retention times of a series of substances with known adsorption coefficients. The adsorption coefficient of the test substance was derived by comparing its retention time with the calibration curve. Detection of the test substance was carried out at 420 nm. Under the test conditions, the adsorption coefficient (i.e., log Koc) of the test substance was determined to be <1.25 (Moller, 2006b).

[LogKoc: 1.25]