Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying Ocular Corrosives and Severe Irritants)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
2-[(3-nitropyrazolo[1,5-a]pyridine-2-yl)oxyethanol
IUPAC Name:
2-[(3-nitropyrazolo[1,5-a]pyridine-2-yl)oxyethanol
Constituent 2
Reference substance name:
IMEXINE stage 4 R0056895A
IUPAC Name:
IMEXINE stage 4 R0056895A
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Test animals / tissue source

Species:
other: Bovine cornea
Details on test animals or tissues and environmental conditions:
Species: bovine cattle.
Origin: bovine eyes were obtained from freshly slaughtered cattle at the abattoir EVA, Saint Pierre sur Dives, France.
Age: bovine cattle were up to 12 months old.
Reason for choice: bovine corneas are recommended by regulatory authorities for this type of study. They are adapted for the evaluation of potential ocular irritants since they are part of the target organ.
Transport from supplier to CiToxLAB France: the eyes were transported to CiToxLAB France at ambient temperature, immerged in buffered Hanks medium containing an antibiotic [Hank’s Balanced Salts Solution (HBSS) plus penicillin/streptomycin (100 units/100 µg/mL final)]. A container with smooth internal surfaces was used for the transport to avoid damage to the corneas.

Preparation of the corneas:
Upon arrival at CiToxLAB France, the selection and preparation of corneas was performed as soon as possible. At each step of the preparation procedure, care was taken to avoid touching the corneas in order not to damage them.

Selection: a careful macroscopic examination was performed on all eyes to detect the presence of any defects (opacity, scratches, pigmentation, etc). Any eyes with defects were discarded. The examination was performed under a lamp, using HBSS in order to keep the eyes moistened and shiny. Particular attention was paid to the corneas and the eyes were swiveled in order to observe the fringe areas and any scratches directly under the light.
Preparation of the selected corneas: the tissues surrounding the eyeball were carefully pulled away and the cornea, surrounded by approximately 2 to 3 mm of sclera, was dissected out. The isolated corneas were stored in HBSS until all corneas had been prepared.
Washing of the corneas: the corneas were washed for 15 minutes, three times, in HBSS plus penicillin/streptomycin (100 units/100 µg/mL final) at room temperature. The corneas were used within a maximum of 24 hours.
Storage of the corneas: as the corneas were not used immediately, they were stored after washing. Each cornea was stored individually in 12 mL of M199 medium containing 5% dextran, plus penicillin/streptomycin, at +4°C, for a maximum of 24 hours before use.

Specific equipment used for the study:
 water bath (32°C),
 identified bovine cornea holders: OPKIT (polypropylene), diameter 18 mm, ref. ED 4004 SB (MC2, Clermont-Ferrand, France),
 electric screwdriver,
 vacuum pump with metal gavage tube,
 OPKIT opacitometer and calibrators (MC2, Clermont-Ferrand, France).


Test system

Vehicle:
other: As the test item is a non-surfactant solid, it was tested in a vehicle. The vehicle was selected according to the results of solubility assays : 0.9% NaCl
Controls:
yes
Amount / concentration applied:
Treatment of corneas
The medium of the anterior chamber was removed and the dose formulation was applied onto the epithelium of the cornea:
The test item was first of all grounded to a fine powder using a mortar and a pestle and then suspended in the required quantity of vehicle. The dose formulation was a yellow suspension. it was prepared at the concentration of 20% (w/v) in the vehicle.
The test item dose formulation was prepared within 4 hours before use and kept at room temperature.As the test item was tested using a 4-hour treatment, the positive control was 20% imidazole solution in 0.9% NaCl (w/v).
As the dose formulation could be applied using a micropipette, a volume of 750 µL (± 8 µL) was used using the closed-chamber method. The dose formulation was introduced into the anterior chamber of the corneal holder, through the dosing holes to cover the epithelial side of the cornea. The dosing holes were then sealed.

For the positive and vehicle controls, a volume of 750 µL ± 8 µL was used for each cornea using the closed-chamber method.


The treatment time of each series of three corneas was carefully measured with a chronometer, starting from the beginning of treatment of the first cornea of each series. Then each further operation (rinsing, measurement, etc.) was carried out in the same order for the three corneas of each series.

After application of the dose formulation, the holders were incubated vertically (cornea positioned horizontally with the treated side uppermost) in a water bath at +32°C (± 1°C), for4h.
Duration of treatment / exposure:
As the test item is a non-surfactant solid, a treatment time of 4 hours (± 5 minutes) was used in the study.
Details on study design:
Assembly of the corneas and the holders
The corneas were carefully examined macroscopically before their assembly in the holders, in order to detect the presence of any defects. Any corneas with defects were discarded. The corneas were then mounted in the corneal holders with the endothelial side against the O-ring of the posterior chamber. Each cornea was identified with the corresponding holder number.

Pre-incubation
For pre-incubation, both chambers of the corneal holder were filled to overflowing with MEM culture media supplemented with 1% fetal bovine serum plus penicillin/streptomycin (cMEM) at room temperature. The posterior chamber was always filled first to maintain the natural concave shape of the cornea.
After making sure that no air bubbles were present within the holder, it was immersed in a water bath, horizontally (cornea positioned vertically), up to approximately three quarters of its height. The holders were pre incubated for 1 hour and 5 minutes (± 5 minutes) at +32°C (± 1°C).

At the end of the pre-incubation period, the medium was removed from both chambers of the holder using a metal gavage tube attached to a vacuum pump to ensure complete evacuation. They were refilled with fresh cMEM (previously heated to +32°C), starting with the posterior chamber and taking care that no air bubbles were present. The chambers were re-sealed and the corneas were examined macroscopically through the holder to detect the presence of any defects. Then, the opacity of the cornea was measured to obtain OPT0.
Corneas that showed any macroscopic defect or an OPT0 value over 7 were discarded.

The test item, the vehicle control and the positive control were tested on three corneas each.

The corneas were distributed as follows:
 the median value of the OPT0 values of all pre-incubated corneas (with OPT0 ≤ 7) was calculated,
 three corneas with opacity values close to the median value were selected as vehicle control corneas,
 the remaining corneas were shared out between test item and positive control treated series using a manual distribution procedure.

To rigorously respect the treatment and any other incubation times, the three corneas from the same series were always processed in the same order at each step.
As the test item was tested using a 4-hour treatment, the positive control was 20% imidazole solution in 0.9% NaCl (w/v).

After treatment of corneas, a rinsing was done to eliminate as much dose formulation as possible, while taking care not to damage the cornea. On completion of the treatment period, the dose formulation was removed from the front opening of the anterior chamber (open-chamber method) and the epithelium was rinsed as follows:
 the chamber was emptied using a metal gavage tube attached to a vacuum pump,
 the corneas were rinsed four times with pre-warmed cMEM containing phenol red (i.e. until the dose formulation had been completely removed from the chamber or until the phenol red was not discolored). Then, the corneas were finally rinsed with pre-warmed cMEM without phenol red.

The rinsing efficiency was visually confirmed by observing the transparency and the color changing of the rinsing medium (containing phenol red). No difficulties were encountered during the rinsing.

The anterior chamber was refilled with fresh pre-warmed cMEM without phenol red. The front cover was replaced. Care was taken to make sure that no air bubbles were present within the holders (by ensuring that each chamber was filled to overflowing with pre-warmed cMEM).
Following the 4-hour treatment, the medium of the posterior chamber was renewed with pre-warmed cMEM (+32°C) and the second opacity measurement (OPT2) was performed directly.

Opacity measurements :
An opacitometer was used to measure light transmission (i.e. the level of opacity) through the center of each mounted cornea. A numerical opacity measurement (arbitrary unit) was displayed and recorded.

Just before the first opacity measurement (i.e. OPT0), the opacitometer was calibrated using specific calibrators. Values obtained for each calibrator were as follows:
 calibrator No. 1: set to 75,
 calibrator No. 2: from 145 to 155,
 calibrator No. 3: from 218 to 232.

Just before the second opacity measurement (i.e. OPT2), the opacitometer was calibrated using the calibrator No. 1 set to 75.

Just after each opacity measurement (OPT0 and OPT2), the calibration of the opacitometer was checked by using the calibrator No. 1. The value obtained was between 73 and 77.

Corneal opacity was determined by reading each holder in the right hand chamber of the calibrated opacitometer, versus an empty holder (without cMEM, cornea and glasses), placed in the left hand chamber.

For opacity measurement, care was taken to make sure that no air bubbles were present within the holders containing corneas (by ensuring that each compartment was filled to overflowing with heated cMEM) and each holder was wiped dry.

Permeability determination:
After the second opacity measurement, the medium of the anterior chamber was removed and the chamber received 1 mL of a fluorescein solution.
As the test item is a non-surfactant solid, the concentration of the fluorescein solution was 5 mg/mL.

Before use, the fluorescein solution was validated. For this purpose, the solution of fluorescein was diluted in cMEM in order to obtain a 5 µg/mL solution and the optical density at a wavelength of 490 nm (OD490 nm) of this dilution was measured. As the value obtained was between 0.850 and 0.940 (see Table 1), the fluorescein solution was validated.

For each series of three corneas, a chronometer started from the fluorescein application time of the first cornea of the series. The holders were incubated vertically (cornea positioned horizontally with the fluorescein-treated side uppermost) in a water bath at +32°C (± 1°C) for 90 minutes (± 5 minutes).

At the end of incubation, the maximum volume of cMEM recoverable from the posterior chamber of each holder was transferred into an identified tube using a single use plastic syringe and a needle. The medium was homogenized prior to determination of OD490 nm, using single-use cuvettes (1 cm path length) and a spectrophotometer (cMEM used as the blank). Any solutions giving an OD490 nm beyond the linear range of the spectrophotometer was diluted in cMEM and measured again. The corresponding OD490 nm was multiplied according to the dilution factor used.

Macroscopic examination:
After permeability determination, the corneas were removed from the holders and observed for opaque spots, other irregularities and any separation of the epithelium.
Then, the corneas were discarded

Results and discussion

In vivo

Irritant / corrosive response data:
No notable opaque spots or irregularities were observed on vehicle control corneas.
Fluoresceine fixation was observed on the corneas treated with the test item.
Opacity, fluoresceine fixation and thickening of the corneas were observed on those treated with the positive control.
IN VITRO IRRITANCY SCORE : All acceptance criteria were fulfilled. The study was therefore considered as valid.
The mean In Vitro Irritancy Score (IVIS) was: 9.

As the test item induced a mean IVIS > 3 and ≤ 55, the eye hazard potential of the test item could not be predicted. The test item could not be identified as inducing serious eye damage (UN GHS Category 1) or as a test chemical not requiring classification for eye irritation or serious eye damage (UN GHS No Category).

Any other information on results incl. tables

Optical density of the fluorescein solution diluted to 5µg/mL: 0.891

Calibration of opacitometer

Before OPT0

After OPT0

Before OPT2

After OPT2

calibratorN°1

75

75

75

76

calibratorN°2

153

np

np

np

calibratorN°3

225

np

np

np

 

GROUP

OPACITY

PERMEABILITY

SCORE

Vehicle control

holder

OPT0

OPT2

OPT2-OPT0

 

OD 490 nm

 

 

41

1

0

-1

 

 

0.026

 

 

32

1

0

-1

 

 

0.036

 

 

20

1

3

2

 

0.022

 

 

MeanSD

 

 

0

1.7

 

0.028

0.007

 

 

 

Test item

Holder

OPT0

OPT2

OPT2-OPT0

cOPT

OD 490 nm

cOD 490 nm

 

15

0

3

3

3

0.014

-0.014

3

17

0

2

2

2

0.027

-0.001

2

44

0

1

1

1

0.031

0.003

1

Mean

SD

 

 

 

2

1

3.8

 

-0.004

0.009

2

0.9

 

Positive control

Holder

OPT0

OPT2

OPT2-OPT0

cOPT

OD 490 nm

cOD 490 nm

 

27

0

91

91

91

5.408

5.380

172

23

0

111

111

111

2.336

2.308

146

37

0

117

117

117

3.176

3.148

164

Mean

SD

 

 

 

106.3

13.6

 

3.612

1.588

161

13.4

np: not performed

OD: optical density

cOD: corrected optical density

cOPT: corrected corneal opacity

SD: standard deviation

OPT0: corneal opacity before treatment

OPT2: corneal opacity after treatment

Vehicle control: 09% NaCl

Test item: R0056895A

Positive control: 20% imidazole solution in 0.9% NaCl

Applicant's summary and conclusion

Interpretation of results:
other: not corrosive
Conclusions:
Under the experimental conditions of this study, the test item, R0056895A, was identified as a test
chemical not requiring classification for eye irritation or serious eye damage (UN GHS No Category).
Executive summary:

The objective of this study was to evaluate the eye hazard potential of the test item, R0056895A. Indeed,

the Bovine Corneal Opacity and Permeability (BCOP) test method can identify chemicals inducing serious

eye damage and chemicals not requiring classification for eye irritation or serious eye damage.

The design of this study was based on the guideline OECD Guideline 437 and the study was performed in

compliance with the OECD Principles of Good Laboratory Practice.

Corneas obtained from freshly slaughtered calves were mounted in corneal holders. Both chambers of the

corneal holder were filled with complemented MEM culture media (cMEM) and pre-incubated for 1 hour

and 5 minutes (± 5 minutes) at +32°C. Three corneas were used for each treated series (test item, positive control and vehicle control).

Before the treatment, a first opacity measurement was performed using an opacitometer.

The test item was applied at the concentrations of 20% (w/v) in the vehicle (0.9% NaCl), in a single experiment using a treatment time of 4 hours and the closed-chamber method. Vehicle and positive controls were applied using the same treatment time and using the closed-chamber method. At the completion of the treatment period, all formulations were removed from the front opening of the anterior chamber and the epithelia were rinsed.

A second opacity measurement was then performed.

After the second opacity measurement, the medium of the anterior chamber was removed and filled with a fluoresceine solution. The holders were then incubated vertically for 90 minutes at +32°C.

At the end of the incubation period, the optical density of the solution from the posterior chamber of each holder was measured in order to determine the permeability of the cornea. Each cornea was then observed for opaque spots and other irregularities.

At macroscopic examinations, fluoresceine fixation was observed on the corneas treated with the test item.

In Vitro Irritancy Score : all acceptance criteria were fulfilled. The study was therefore considered as valid.

The mean In Vitro Irritancy Score (IVIS) was: 2.

As the test item induced a mean IVIS ≤ 3, the test item was considered as a test chemical not requiring

classification for eye irritation or serious eye damage (UN GHS No Category).

Under the experimental conditions of this study, the test item, R0056895A, was identified as a test

chemical not requiring classification for eye irritation or serious eye damage (UN GHS No Category).