Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1994
Report Date:
1994

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to
Guideline:
other:
Qualifier:
according to
Guideline:
ISO 1523 (Determination of flash point - Closed cup equilibrium method)
Type of method:
equilibrium method closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Flash point
Flash point:
139 °C
Atm. press.:
101.325 kPa
Remarks on result:
other:

Applicant's summary and conclusion