Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental Starting Date: 0/22/2015; Experimental Completion Date: 06/2/2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ISO 13320-1: Particle Size Analysis – Laser Diffraction Methods
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
Identification: FAT 20036/G TE Lot.AT-0033439900
Appearance: Blue powder
Mass median aerodynamic diameter:
70.737 µm
Percentile:
D50
Mean:
70.737 µm
Remarks on result:
other: Median particle size of the test item
No.:
#1
Size:
7.73 µm
Remarks on result:
other: L10
No.:
#2
Size:
70.737 µm
Remarks on result:
other: L50 (median particle size)
No.:
#3
Size:
104.507 µm
Remarks on result:
other: L90
Conclusions:
Median particle size for FAT 20036/G TE was 70.737 μm.
Executive summary:

The particle size distribution of FAT 20036/G TE has been determined, using a procedure designed to be compatible CIPAC MT 187: Particle Size Analysis by Laser Diffraction and ISO 13320-1: Particle Size Analysis – Laser Diffraction Methods.

Based on the findings of the study, particle size data acquired for FAT 20036/G TE is as follows:

L10: 7.730 μm

L50 (median particle size): 70.737 μm

L90: 104.507 μm

Description of key information

The particle size distribution of FAT 20036/G TEhas been determined, using a procedure designed to be compatible CIPAC MT 187: Particle Size Analysis by Laser Diffraction and ISO 13320-1: Particle Size Analysis – Laser Diffraction Methods.

Based on the findings of the study, particle size data acquired for FAT 20036/G TE is as follows:

L10: 7.730 μm

L50 (median particle size): 70.737 μm

L90: 104.507 μm


Additional information