Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study and GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
N4-[3-(1H-imidazol-1-yl)propyl]-2-methylbenzene-1,4-diamine trihydrochloride
EC Number:
700-345-3
Cas Number:
515851-08-8
Molecular formula:
C13H21Cl3N4
IUPAC Name:
N4-[3-(1H-imidazol-1-yl)propyl]-2-methylbenzene-1,4-diamine trihydrochloride
Constituent 2
Reference substance name:
[TN]Kn 172[/TN][SPEC][/SPEC][AM]96.2%[/AM]
IUPAC Name:
[TN]Kn 172[/TN][SPEC][/SPEC][AM]96.2%[/AM]
Details on test material:
Batch No. Kn-Gi 9328-182

Results and discussion

Small-scale preliminary testsopen allclose all
Parameter:
other: More sensitive to shock than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Parameter:
other: More sensitive to friction than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Parameter:
other: Explosive under influence of flame
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Parameter:
other: Explosive (not specified)
Remarks:
migrated information
Remarks on result:
negative (not further specified)

Any other information on results incl. tables

a) The test item Kn 172 is not thermally sensitive

b) The test item Kn 172 is not mechanical sensitive with respect to shock

c) The test item Kn 172 is not mechanical sensitive with respect to friction

Applicant's summary and conclusion

Conclusions:
a) The test item Kn 172 is not thermally sensitive
b) The test item Kn 172 is not mechanical sensitive with respect to shock
c) The test item Kn 172 is not mechanical sensitive with respect to friction