Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: No GLP study, but test procedure in accordance with generally accepted scientific standards and described in sufficient detail

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
no guideline followed
Deviations:
not applicable
Principles of method if other than guideline:
The particle size distribution is analysed by laser scattering analysis.
GLP compliance:
no
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
sodium 4-[(4-chlorobenzoyl)amino]benzoate
EC Number:
807-461-4
Cas Number:
1489170-67-3
Molecular formula:
C14H9ClNNaO3
IUPAC Name:
sodium 4-[(4-chlorobenzoyl)amino]benzoate
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Mean:
1.968 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
1.013 µm
Remarks on result:
other: (respirable fraction: < 4µm)
Percentile:
D50
Mean:
1.968 µm
Remarks on result:
other: (respirable fraction: < 4µm)
Percentile:
D90
Mean:
3.041 µm
Remarks on result:
other: (respirable fraction: < 4µm)

Applicant's summary and conclusion

Conclusions:
The particle size distribution was investigated based on the theory of laser diffraction with the following results:
D10 = 1.013 μm
D50 = 1.968 μm= mass median diameter (MMD)
D90 = 3.041 μm (respirable fraction: < 4µm)
The study was performed in accordance with generally accepted scientific standards and described in sufficient detail and therefore reliability of Klimisch 2 has been assigned.