Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report date:
2000

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
no
Type of method:
dynamic method

Test material

Constituent 1
Reference substance name:
Silan CMM2
IUPAC Name:
Silan CMM2
Test material form:
other: liquid

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
43 hPa
Temp.:
38 °C
Vapour pressure:
104 hPa
Temp.:
50 °C
Vapour pressure:
177 hPa

Any other information on results incl. tables

Condesner temperature: - 30 °C.

Substances which do not condense at -30 °C are not determined with this method.