Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Inhalation:

Move exposed person to fresh air. Keep person warm and at rest. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. Get medical attention if symptoms occur. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Ingestion:

No special measures required.

Skin contact:

No special measures required.

Eye contact:

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention if irritation occurs.

Fire-fighting measures

EXTINGUISHING MEDIA:

Suitable:

In case of fire, use water spray (fog), foam, dry chemical or CO2.

Not suitable:

None known.

Special exposure hazards:

No specific fire or explosion hazard.

Secial protective equipment for fire-fighters:

Fire-fighters should wear appropriate protective equipment and selfcontained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

Accidental release measures

Personal precautions:

No action shall be taken involving any personal risk or without suitable training. Keep unnecessary and unprotected personnel from entering. Avoid breathing dust. Provide adequate ventilation. Put on appropriate personal protective equipment. Hazard of slipping on spilt product.

Environmental precautions:

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

Large spill:

Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Vacuum or sweep up material and place in a designated, labelled waste container. Dispose of via a licensed waste disposal contractor.

Small spill:

Move containers from spill area. Vacuum or sweep up material and place in a designated, labelled waste container. Dispose of via a licensed waste disposal contractor.

Handling and storage

Handling:

No special measures required.

Storage:

Do not store above the following temperature: 80°C (176°F). No special measures required.

Packing materials:

Recommended: Use original container.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
not applicable
Shippingopen allclose all
Labels:
not applicable
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
not applicable
Shippingopen allclose all
Labels:
not applicable
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
not applicable
Shipping information
Proper shipping name and description:
not applicable
Chemical name:
triiron tetraoxide
Labels:
not applicable
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
not applicable
Shipping information
Proper shipping name and description:
not applicable
Chemical name:
triiron tetraoxide
Labels:
not applicable
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Exposure limit values:

Not available.

Recommended monitoring procedures:

If this product contains ingredients with exposure limits, personal, workplace atmosphere or biological monitoring may be required to determine the effectiveness of the ventilation or other control measures and/or the necessity to use respiratory protective equipment. Reference should be made to monitoring standards, such as the following: European Standard EN 689 (Workplace atmospheres - Guidance for the assessment of exposure by

inhalation to chemical agents for comparison with limit values and measurement strategy) European Standard EN 14042 (Workplace atmospheres - Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents) European Standard EN 482 (Workplace atmospheres - General requirements for the performance of procedures for the measurement of chemical agents) Reference to national guidance documents for methods for the determination of hazardous substances will also be required.

RISK MANAGEMENT MEASURES, OCCUPATIONAL EXPOSURE CONTROLS:

Technical measures:

Use only with adequate ventilation. If user operations generate dust, fumes, gas, vapour or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits.

PERSONAL PROTECTION MEASURES:

Respiratory protection:

Recommended: Dust-protection mask

Hand protection:

Recommended: gloves

Eye protection:

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If operating conditions cause high dust concentrations to be produced, use dust goggles.

Recommended: safety glasses with side-shields

Skin protection:

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Hygiene measures:

Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking and using the lavatory and at the end of the working period. Appropriate techniques should be used to remove potentially contaminated clothing. Wash contaminated clothing before reusing. Ensure that eyewash stations and safety showers are close to the workstation location.

ENVIRONMENTAL EXPOSURE CONTROLS:

Technical measures:

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Stability and reactivity

Stability:

The product is stable.

Possibility of hazardous reaction:

Under normal conditions of storage and use, hazardous reactions will not occur.

Conditions to avoid: At temperatures above 80 °C the product may become unstable and oxidise. This generates additional heat which, under unfavourable conditions, may result in the combustion of flammable materials. The product should therefore not be stored near heat sources.

Hazardous decomposition products:

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

Disposal considerations

Methods of disposal:

Examine possibilities for re-utilisation. Product residues and uncleaned empty containers should be packaged, sealed, labelled, and disposed of or recycled according to relevant national and local regulations. Where large quantities are concerned, consult the supplier. When uncleaned empty containers are passed on, the recipient must be warned of any possible hazard that may be caused by residues. For disposal within the EC, the appropriate

code according to the European Waste List (EWL) should be used. It is among the tasks of the polluter to assign the waste to waste codes specific to industrial sectors and processes according to the European Waste List (EWL).

Hazardous waste:

Within the present knowledge of the supplier, this product is not regarded as hazardous waste, as defined by EU Directive 91/689/EEC.