Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Remarks:
Determination of flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Data from a study performed according to a standard method; cited in a reputable database; adequate for assessment.
Qualifier:
equivalent or similar to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Principles of method if other than guideline:
Method not described, assumed to be similar to standard methods.
GLP compliance:
no
Type of method:
closed cup
Flash point:
ca. 61.97 °C
Remarks on result:
other: additional details not provided in data source
Conclusions:
The measured flash point of MEKO is 61.97 degrees Celcius

Description of key information

61.97 °C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
61.97 °C

Additional information

Data from a study performed according to a standard method; cited in a reputable database; adequate for assessment.