Registration Dossier

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Emergency measure - Eyes: No specific treatment.

Fire-fighting measures

Recommended extinguishing agent: In case of fire, the usual extinguishers are recommended
e.g: water, CO2, foam, dry powder). The substance itself is
not flammable. Nevertheless, in case of fire, nitrogen
oxides and sulphur dioxide (and chromium oxide smoke ?) may
be produced; it is therefore recommended that a respirator
be worn.

Accidental release measures

Emergency measures in case of spillage: Collect the product while keeping it dry and take it to a
controlled disposal area or incinerate it in a suitable
installation. Absorb spilled solutions with a suitable
product (e.g. sawdust) and incinerate in a suitable
installation.

Handling and storage

Handling: The usual precautions for handling chemicals should be
observed. Wear protective clothing and respirators in case
of inadequate ventilation.

Storage: No special precautions necessary. Should be kept in closed
packages in a dry storage area.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions necessary. The product should be
transported in suitable packaging, for example, in
polythene bags inside steel drums.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Disposal considerations

Industry - Possibility of recovery/recycling: In normal usage, the substance is irreversibly attached to
the aluminium. Unused material can be removed from the
treatment bath by either precipitation with trivalent iron
or aluminium salts or absorption on activated charcoal.

Industry - Possibility of neutralisation: Not applicable

Industry - Possibility of destruction: controlled discharge: at a licensed waste disposal site (but see Declaration for
necessary precautions)

Industry - Possibility of destruction - incineration: in an appropriate incinerator (for precautions, see item
2.3.4) Water purification systems: Not recommended

Public at large - Possibility of recovery/recycling: The substance itself will not enter the public domain.