Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 30, 2009 - March 15, 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study was performed in accordance with the OECD Guideline 113.
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
no
Remarks:
Not required by the authority

Test material

Constituent 1
Chemical structure
Reference substance name:
Nitrosylsulphuric acid
EC Number:
231-964-2
EC Name:
Nitrosylsulphuric acid
Cas Number:
7782-78-7
Molecular formula:
HNO5S
IUPAC Name:
hydroxy(nitrosooxy)sulfane dioxide
Test material form:
other: liquid
Details on test material:
Identity: Confirmed by density
Storage: RT, dry
Expiry Date: November 20, 2011

Results and discussion

For thermal stability study

Test substance thermally stable:
yes
Operating temperature
Operating temp.:
500 °C
Remarks on result:
other: up to a maximum temperature of 500 °C
Sublimation:
not determined
Transformation products:
not measured

For study on stability to sunlight

Test substance stable to sunlight:
not determined

For study on stability to metals

Test substance stable to metals / metal ions:
not determined

Any other information on results incl. tables

Two DSC-measurements in closed glass crucibles showed neither endothermic nor exothermal effects up to a maximum temperature of 500 °C.

Applicant's summary and conclusion

Conclusions:
Test item is up to 500 °C thermal stable.
Executive summary:

The study was performed in accordance with the OECD Guideline 113 in year 2009/2010.

The test item LZ5593 showed in closed glass crucibles neither endothermic nor exothermal effects up to a maximum temperature of

500 °C