Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 273-110-1 | CAS number: 68938-03-4 The complex combination of hydrocarbons produced by the distillation of products from the hydrogenation of isononanal. It consists predominantly of C6 olefins and paraffins and C9 alcohols and aldehydes and boiling in the range of approximately 110°C to 202°C (230°F to 396°F).
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 8 January 2010-12 january 2010
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: A GLP study undertaken to current EU and OECD test guidelines
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- HPLC estimation method
- Media:
- soil
- Radiolabelling:
- no
- Test temperature:
- 25°C
- Details on study design: HPLC method:
- EQUIPMENT
- Apparatus: Liquid Chromatograph
- Type: Agilent 1200 Series
- Type, material and dimension of analytical (guard) column: Hypersil CPS (25 cm x 4.6 mm internal diameter)
- Detection system: UV set at 210 nm
MOBILE PHASES
- Type: Methanol:water (55:45 v/v)
- Experiments with additives carried out on separate columns: no
- pH: no data
- Solutes for dissolving test and reference substances: none
DETERMINATION OF DEAD TIME
- Method: by an inert substance which is not retained by the column
REFERENCE SUBSTANCES
- Identity: formamide
DETERMINATION OF RETENTION TIMES
- Quantity of test substance introduced in the column: 20 µl at 212 mg/l
- Quantity of reference substances: 20 µl at 200 mg/l
- Intervals of calibration: calibrated as part of the study
REPETITIONS
- Number of determinations: 2
EVALUATION
- Calculation of capacity factors k': tr-to/to
- Calculation of retention times: tr-to
- Determination of the log Koc value: log10Koc = 3.52 log10k + 4.16 - Type:
- log Koc
- Value:
- 3.2 dimensionless
- Temp.:
- 25 °C
- Type:
- Koc
- Value:
- 1 750 L/kg
- Temp.:
- 25 °C
- Details on results (HPLC method):
- - Retention times of reference substances used for calibration: 3.155 mins
- Details of fitted regression line (log k' vs. log Koc): log10Koc = 3.52 log10k + 4.16
- Graph of regression line attached: yes
- Average retention data for test substance: 4.889 mins (additional peak with shorter retention time of 3.151 min, but not included in calculation) - Conclusions:
- Oxooil LS 9 was determined to have a log10Koc value of 3.2 (equivalent Koc = 1750).
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- (Q)SAR
- Adequacy of study:
- supporting study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
- Justification for type of information:
- 1. SOFTWARE
EpiSuite v4.11, US EPA, 2012
2. MODEL (incl. version number)
KOCWIN v2.00 (MCI method)
3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
see atteched file (Koc_QSAR justification.pdf)
4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
- Defined endpoint: Koc
MCI (molecular connectivity index) method
The equation derived by the non-polar (no correction factor) regression is:
log Koc = 0.5213 MCI + 0.60
(n = 69, r2 = 0.967, std dev = 0.247, avg dev = 0.199)
for comparison, the previous version of PCKOCWIN used a very similar equation:
log Koc = 0.53 MCI + 0.62
Adding in the correction factor regression yields the final MCI equation:
log Koc = 0.5213 MCI + 0.60 + ΣPfN
where ΣPfN is the summation of the products of all applicable correction factor coefficients multiplied by the number of times (N) that factor is counted for the structure.
- Defined domain of applicability:
Currently there is no universally accepted definition of model domain. However, users may wish to
consider the possibility that log P estimates are less accurate for compounds outside the MW
range of the training set compounds, and/or that have more instances of a given fragment than the
maximum for all training set compounds. It is also possible that a compound may have a functional
group(s) or other structural features not represented in the training set, and for which no fragment
coefficient was developed. These points should be taken into consideration when interpreting
model results.
Training Set Molecular Weights:
Minimum MW: 32.04
Maximum MW: 665.02
Average MW: 224.4
Validation Molecular Weights:
Minimum MW: 73.14
Maximum MW: 504.12
Average MW: 277.8
- Appropriate measures of goodness-of-fit and robustness and predictivity:
Overall, the MCI methodology is somewhat more accurate than the Log Kow methodology, although both methods yield good results. If the Training datasets are combined in to one dataset of 516 compounds (69 having no corrections plus 447 with corrections), the MCI methodology has an r2, standard deviation and average deviation of 0.916, 0.330 and 0.263, respectively.
5. APPLICABILITY DOMAIN
- Descriptor domain: The components of the substance are within the molecular weight range of the training set compounds, and all fragments are represented in the training set. Thus, it is concluded, that the substance is within the applicability domain.
- Similarity with analogues in the training set: several linear and branched alkanes and alkenes, which are considered to be similar, are present in the training set.
6. ADEQUACY OF THE RESULT
The QSAR prediction is valid and of good reliability. Thus, the result is adequate for chemical safety assessment. - Principles of method if other than guideline:
- Estimation of the Koc of the components by QSAR (EpiSuite v4.11, US EPA, 2012; KOCWIN v2.00 (MCI method))
- GLP compliance:
- no
- Type of method:
- other: QSAR
- Remarks:
- EpiSuite v4.11, US EPA, 2012; KOCWIN v2.00 (MCI method)
- Key result
- Type:
- Koc
- Remarks:
- weighted mean
- Value:
- 369.6 L/kg
- Temp.:
- 25 °C
- Type:
- Koc
- Value:
- >= 26.94 - <= 436.8 L/kg
- Temp.:
- 25 °C
- Conclusions:
- The Koc of the constituents was estimated using EpiSuite v4.11, US EPA, 2012, KOCWIN v2.00 (MCI method) in batch mode, resulting in Koc values ranging from 26.94 to 436.8 L/kg with a weighted mean Koc of 369.6.
Referenceopen allclose all
A value of log10Koc for Oxooil LS 9 of 3.2 was obtained. This result was determined for the primary chromatographic component, although it was evident that there were some minor components of shorter retention time and, hence, lower log10Koc value.
for details see attachment
Description of key information
Oxooil LS9 has a Koc value of 1750 (log Koc = 3.2), measured according to guideline OECD 121.
Key value for chemical safety assessment
- Koc at 20 °C:
- 1 750
Other adsorption coefficients
- Type:
- log Kp (solids-water in soil)
- Value in L/kg:
- 1.54
- at the temperature of:
- 20 °C
Other adsorption coefficients
- Type:
- log Kp (solids-water in sediment)
- Value in L/kg:
- 1.94
- at the temperature of:
- 20 °C
Other adsorption coefficients
- Type:
- log Kp (solids-water in suspended matter)
- Value in L/kg:
- 2.24
- at the temperature of:
- 20 °C
Other adsorption coefficients
- Type:
- log Kp (solids-water in raw sewage sludge)
- Value in L/kg:
- 2.72
- at the temperature of:
- 20 °C
Other adsorption coefficients
- Type:
- log Kp (solids-water in settled sewage sludge)
- Value in L/kg:
- 2.72
- at the temperature of:
- 20 °C
Other adsorption coefficients
- Type:
- log Kp (solids-water in activated sewage sludge)
- Value in L/kg:
- 2.81
- at the temperature of:
- 20 °C
Other adsorption coefficients
- Type:
- log Kp (solids-water in effluent sewage sludge)
- Value in L/kg:
- 2.81
- at the temperature of:
- 20 °C
Additional information
Oxooil LS9 has a Koc value of 1750 (log Koc = 3.2), measured according to guideline OECD 121. This result was determined for the primary chromatographic component, although there were some minor components of shorter retention time and, hence, lower Koc value.
Since the substance is rather volatile and therefore difficult to test, in addition, the Koc of the constituents of Oxooil LS9 was estimated using EpiSuite v4.11, US EPA, 2012, KOCWIN v2.00 (MCI method) in batch mode, resulting in Koc values ranging from 26.94 to 436.8 L/kg with a weighted mean Koc of 369.6 (log Koc 2.57). In conclusion, the result obtained in the study using the HPLC method, which is used as key value for this endpoint, might overestimate the Koc, especially since only the main peak with the higher retention time was taken into consideration.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.