Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10/18/2011 to 08/28/2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study was performed according to guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pour point

Test material

Constituent 1
Chemical structure
Reference substance name:
1,6-bis({2,2-bis[(undecyloxy)methyl]butyl}) hexanedioate
EC Number:
700-772-5
Cas Number:
1190961-28-4
Molecular formula:
N/A - too complex
IUPAC Name:
1,6-bis({2,2-bis[(undecyloxy)methyl]butyl}) hexanedioate
Test material form:
other: liquid
Details on test material:
- Physical state: straw colored liquid
- Purity test date: 100% as UVCB
- Expiration date of the lot/batch: 17 September 2012
- Storage condition of test material: room temperature, in the dark

Results and discussion

Melting / freezing point
Melting / freezing pt.:
-6 °C
Atm. press.:
760 mm Hg
Remarks on result:
other: Pour Point

Applicant's summary and conclusion

Conclusions:
The pour point of the test item was determined to be -6 ± 3 °C (267 ± 3 K).
Executive summary:

Test System

The determination was carried out using a procedure designed to be compatible with Method AI Melting/Freezing Temperature of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 102 of the OECD Guidelines for Testing of Chemicals, 27 July 1995.

Principle of the Test

An aliquot of test item is placed in a glass vessel of specified dimensions which is then placed inside a glass jacket.  After preliminary heating of the apparatus, the test item is cooled and examined at intervals for flow characteristics. The lowest temperature at which movement is observed is recorded as the pour point.

Result

The pour point of the test item was determined to be -6 ± 3 °C (267 ± 3 K).