Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 216-133-4 | CAS number: 1506-02-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption
- Remarks:
- adsorption/desorption
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Special protocol developed for sampling by Royal haskoning: "Sampling Instructions for Analysis of Polycyclic Musks in Activated Sludge and Sewage Treatment Plant Effluent". Included in study as Annex G.
- Principles of method if other than guideline:
- The activated sludge- water partitioning coefficient was determined by measuring AHTN in samples obtained throughout Southern Europe and Berlin. Effluent and sludge were sampled simultaneously.
- GLP compliance:
- yes
- Media:
- sewage sludge
- Radiolabelling:
- yes
- Analytical monitoring:
- not specified
- Details on sampling:
- Sampling was conducted under normal dry weather conditions in the period between May and September 2004. The sampling in Berlin took place in May and October 2004. In order to assess the temporal and spatial variability, stack samples of activated sludge and effluent were taken at four times with intervals of at least 14 days for Italy, Spain and Greece and two times for Berlin.
- Computational methods:
- The analysis of the concentrations was based on the 10log transform of the observed concentrations.
- Type:
- Kd
- Value:
- 9 120
- % Org. carbon:
- > 240 - < 290
- Remarks on result:
- other: g/kg dw
- Recovery of test material:
- Analytical recovery in sludge ranged from 76 to 125% with an average of 105% and coefficient of variation (CV) of 12.2%. In effluent, the analytical recovery ranged from 68 to 167% with an average of 91% and CV of 14.4%.
Local recovery in sludge ranged from 72 to 101% with an average of 86% and coefficient of variation (CV) of 14%. In effluent, the analytical recovery ranged from 44 to 127% with an average of 82% and CV of 20%. - Transformation products:
- not measured
- Statistics:
- For AHTN in sludge and effluent it can be concluded that the observed variance is mainly caused by the local differences. The variation between sludge samples is only 2.5 % due to analytical error, whereas for effluent samples the analytical error contributes for 21 % in the AHTN variability.
- Validity criteria fulfilled:
- not applicable
- Remarks:
- AHTN sampled at locations in Europe
- Conclusions:
- Assuming that Kd is constant with a varying AHTN concentration, the log Kd is 3.96.
- Executive summary:
Concentrations of the polycyclic musks HHCB and AHTN have been measured in 15 sewage treatment plants in Southern Europe (Italy, Spain and Greece) and 3 plants in Berlin, Germany. No correlation could be found between the type of plant design or performance and the concentration level. Differences between treatment plants appear to be related to local differences in the per capita use volume of the local population. The ratios between concentrations in sludge and effluents are generally in good agreement with equilibrium partitioning; however, local differences between plants may occur. These differences may be explained by a non-linear adsorption isotherm to the suspended solids on the one hand and partitioning to dissolved organic macromolecules on the other hand. Based on comparison of recent available data for more than 110 plants in other countries of Europe, the 90th- percentile values of Southern Europe represent the realistic worst-case for Europe.
The median of the AHTN concentration in sludge is 5.5 mg/kg dw and the 90th percentile 11 mg/kg dw. In the effluent, the median AHTN concentration is 0.6µg/kg and the 90th percentile 1.3µg/l.
- Endpoint:
- adsorption / desorption
- Remarks:
- adsorption
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Study period:
- 22 November 2000 - 16 October 2002
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: A thesis describing the research conducted by a Ph.D. student at the Institute for Risk Assessment Sciences (IRAS), University of Utrecht (NL).
- Reason / purpose for cross-reference:
- reference to same study
- Guideline:
- other: described in thesis
- Principles of method if other than guideline:
- Biodegradation rate constants of AHTN in the aeration tank of a sewage treatment plant (STP) are studied in vitro. A general model is described to determine the rate-limiting factor in the biodegradation process, from which the Koc can be calculated.
- GLP compliance:
- not specified
- Type of method:
- other:
- Media:
- sewage sludge
- Radiolabelling:
- no
- Test temperature:
- Room temperature
- Analytical monitoring:
- not required
- Details on sampling:
- Experiments were conducted in duplicate with activated sludge obtained from the oxidation tank of the STP in De Bilt (The Netherlands) on November 22, 2000. Sludge was collected and aerated to maintain bacterial activity during transportation.
- Computational methods:
- The rate constant of microbial degradation and the rate constant of evaporation are used to calculated the Koc.
The microbial degradation is calculated by taking the quotient of the rate constants k1 and k2 representing the mass transfer of the chemical from the organic to the aqueous phase, and from the aqueous to the organic phase, respectively. - Type:
- log Koc
- Remarks:
- "Apparent" value that is based on the biodegradation rate constants of chemicals in activated sludge.
- Value:
- 3.1
- Remarks on result:
- other: Organic carbon is determined but not reported. Temperature is probably room temperature.
- Type:
- log Koc
- Remarks:
- True partition coefficient
- Value:
- 3.8
- Remarks on result:
- other: Organic carbon is determined but not reported. Temperature is room temperature.
- Recovery of test material:
- Recoveries of the procedure were between 85-110%.
- Transformation products:
- not measured
- Details on results (Batch equilibrium method):
- The organic carbon content was stable during the entire experiment.
Model curves, shown in Figure 1 (attached), are in agreement with the measured values, and it can be concluded that the model describes the data rather well.
Koc obtained from the model is lower than the independently measured data. - Validity criteria fulfilled:
- yes
- Remarks:
- based on recovery
- Conclusions:
- Microbial degradation is the rate-limiting step in the biodegradation in an aeriation tank with a half life of 92h. The calculated Koc is 3.1 based on the biodegradation rate constants of chemicals in activated sludge.
- Executive summary:
A mathematical model to determine free concentration based biodegradation rate constants of chemicals in activated sludge was developed. The model is based on the assumption that only the free concentration is available for microbial degradation and therefore two processes can limit the biodegradation rate. Either desorption of the chemical from the matrix to the aqueous phase, or the microbial degradation capacity is rate-limiting. Calculations show that a comparison of the decrease of free and total concentrations of the chemicals in time, together with an independent measurement of the organic carbon/water partition coefficient (Koc gives information about the rate-limiting step of the biodegradation process). This information can be used as a tool to optimize the removal of chemicals in STPs. Experimental results show that for AHTN the biodegradation half-life of AHTN in the aeration tank is 92h, and that microbial degradation itself is the rate-limiting process.
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: According to OECD guideline, but no GLP compliance data included.
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to other study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- GLP compliance:
- not specified
- Type of method:
- HPLC estimation method
- Media:
- other: no media
- Radiolabelling:
- no
- Details on study design: HPLC method:
- AHTN was separeted by chromatography under standard HPLC conditions on a cyano column. The retention times were determined. The corresponding capacity factors (k’ and log k’) were calculated from the dead volume of the HPLC system.
The log k’ values of the reference substances and their coefficients of adsorption (log KOC) were used to calculate a calibration function (log k’ against log KOC). The coefficients of adsorption (log KOC) of AHTN was calculated from the log k’ values using calibration lines.
Reference substances were Formamid, Acetanilid, Atrazin, Monuron, Triapenthenol, Linuron, Fenthion, Trifluralin.
HPLC Parameter
Pump: Gynkotek M480 Gradientenpump
Autosampler/Injector: Gynkotek GINA 160
Column: Zorbax CN, 5 μm, 250 x 4.6 mm
Precolumn: Zorbax CN, 5 μm, 10 x 4.6 mm
Mobile Phase: Methanol / Water (60% / 40% (v/v)
Rate: 1,0 mL/min
Injection volume: 20 μL
Substance injected: 1.0 - 1,6 μg
Temperature: 40 °C
Detector: Gynkotek UVD 160S/320S
Data system: Gynkosoft Vers.5.50 - Analytical monitoring:
- not required
- Type:
- log Koc
- Value:
- 3.41
- Temp.:
- 40 °C
- Type:
- Koc
- Value:
- 2 563
- Temp.:
- 40 °C
- Transformation products:
- not measured
- Conclusions:
- Log Koc is 3.41, indicating a strong adsorption to soils.
- Executive summary:
The log Koc and Koc were estimated using the HPLC screening method according to draft OECD Guideline 121. Suitable test and reference substances were subjected to chromatography under standard HPLC conditions on a cyano column and the retention times were determined. The corresponding capacity factors (k’ and log k’) were calculated from the dead volume of the HPLC system and the retention times determined. The log k’ values of the reference substances and their coefficients of adsorption (log Koc) were used to calculate a calibration function (log k’ against log Koc). The coefficients of adsorption (log Koc) of AHTN was calculated from the log k’ values using calibration lines. The estimation of the adsorption coefficients (log Koc) produced a relatively high value of 3.41. Other polycyclic musks were also examined and in this range. This indicates strong sorption of the substances to soils.
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: According to OECD guideline, but no GLP compliance data included.
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to other study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 106 (Adsorption - Desorption Using a Batch Equilibrium Method)
- GLP compliance:
- not specified
- Type of method:
- HPLC estimation method
- Media:
- soil
- Radiolabelling:
- no
- Details on study design: HPLC method:
- AHTN was separeted by chromatography under standard HPLC conditions on a cyano column. The retention times were determined. The corresponding capacity factors (k’ and log k’) were calculated from the dead volume of the HPLC system.
- Analytical monitoring:
- not required
- Details on test conditions:
- Soil used: Borstel soil (sandy); Latrop soil (clayey); Friesland soil (humic).
- Type:
- Kd
- Value:
- 162.6
- Temp.:
- 20 °C
- % Org. carbon:
- 1.2
- Remarks on result:
- other: Borstel soil; pH=5.4
- Type:
- Kd
- Value:
- 150
- Temp.:
- 20 °C
- % Org. carbon:
- 3.1
- Remarks on result:
- other: Latrop soil; pH=6.1
- Type:
- Kd
- Value:
- 660
- Temp.:
- 25 °C
- % Org. carbon:
- 5.8
- Remarks on result:
- other: Friesland (D); pH=5.1
- Type:
- Koc
- Value:
- 13 550
- Temp.:
- 20 °C
- % Org. carbon:
- 1.2
- Remarks on result:
- other: Borstel soil; pH=5.4
- Type:
- Koc
- Value:
- 4 839
- Temp.:
- 20 °C
- % Org. carbon:
- 3.1
- Remarks on result:
- other: Latrop soil; pH=6.1
- Type:
- Koc
- Value:
- 11 383
- Temp.:
- 20 °C
- % Org. carbon:
- 5.1
- Remarks on result:
- other: Friesland (D); pH=5.1
- Recovery of test material:
- Soil samples were extracted to calculate a total mass balance. The recoveries for the Borstel soil (sandy); Latrop soil (clayey); Friesland soil (humic) and seage sludge (Klärschlamm) were 113%, 117, 180% and 280%. The balances were above 100% due to the presence of AHTN in the samples prior to addition. The latter recovery was so extemely high that no absorption coefficient was calculated.
- Sample no.:
- #1
- Duration:
- 24 h
- % Adsorption:
- 76.4
- Sample no.:
- #2
- Duration:
- 24 h
- % Adsorption:
- 82.7
- Sample no.:
- #3
- Duration:
- 24 h
- % Adsorption:
- 94.1
- Sample no.:
- #4
- Duration:
- 24 h
- % Adsorption:
- 96.8
- Sample no.:
- #1
- Duration:
- 24 h
- % Desorption:
- 21.5
- Sample no.:
- #2
- Duration:
- 24 h
- % Desorption:
- 18.1
- Sample no.:
- #3
- Duration:
- 24 h
- % Desorption:
- 4.9
- Sample no.:
- #4
- Duration:
- 24 h
- % Desorption:
- 1.5
- Transformation products:
- not measured
- Details on results (Batch equilibrium method):
- Adsorption equilibria reached after about 2 hours.
For isotherm and desorption test, an additional 24 hours was selected. - Validity criteria fulfilled:
- yes
- Remarks:
- Control samples and blanks were included.
- Conclusions:
- AHTN strongly absorbs to the soil samples. The log Koc ranged from 4800-13600 cm3/g for sandy, clay and humic soil.
- Executive summary:
The sorption characteristics of AHTN was determined on three representative soils in accordance with OECD Guideline 106. The soils differed in their characteristics: Borstel soil (sandy); Latrop soil (clayey); Friesland soil (humic). The factors determined were adsorption kinetics, adsorption isotherms (according to Freundlich) and the desorption behaviour. The experiments regarding adsorption kinetics showed that the sorption equilibria were reached after a short period (approx. 2 hours). The Freundlich adsorption isotherms showed good correlations for all substances and soils. The adsorption coefficients (Kd) were in the range of 150 to 660 cm3/g. The normalization to the organic carbon content in the soils yielded Koc values of between 4800 and 13600 cm3/g for Tonalid. These values show that the substances are bound very strongly to the soils. The desorption tests showed that the adsorption is not reversible and a maximum of only 1-21.5% of the sorbed quantities of the substances was desorbed.
- Endpoint:
- adsorption / desorption
- Remarks:
- adsorption
- Type of information:
- (Q)SAR
- Adequacy of study:
- weight of evidence
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: KOCWIN v2.00 - Model to estimate the soil adsorption coeffiecient (Koc) of organic compounds, v2.00, February 2009, US Environmental Protection Agency (2000-2008).
- Justification for type of information:
- QSAR prediction: migrated from IUCLID 5.6
- Reason / purpose for cross-reference:
- reference to same study
- Qualifier:
- no guideline required
- Principles of method if other than guideline:
- Estimation methods for predicting Koc values for hydrophobic organic compounds based upon the octanol/water partition coefficient.
- GLP compliance:
- no
- Computational methods:
- log Kow can be used to estimate Koc for non-polar compounds. The equation derived by the non-polar (no correction factor) regression is:
log Koc = 0.55313 Log Kow + 0.9251 + ΣPfN
(n = 68, r2 = 0.877, std dev = 0.478, avg dev = 0.371)
where ΣPfN is the summation of the products of all applicable correction factor coefficients multiplied by the number of times (N) that factor is counted for the structure.
Reference: Doucette, W.J. 2000. Soil and sediment sorption coefficients. In: Handbook of Property Estimation Methods, Environmental and Health Sciences. R.S. Boethling & D. Mackay (Eds.), Boca Raton, FL: Lewis Publishers (ISBN 1-56670-456-1). - Type:
- log Koc
- Value:
- > 4.1 - < 4.3
- Remarks on result:
- other: Method based on Log Kow with a correction factor for the ketone
- Type:
- log Koc
- Value:
- > 4.68 - < 4.95
- Remarks on result:
- other: Method based on Log Kow for non-polar molecules
- Transformation products:
- not measured
- Statistics:
- Linear regression, for details see Koc WIN model
- Validity criteria fulfilled:
- not applicable
- Conclusions:
- log Koc estimated from log Kow is 4.2.
- Executive summary:
The Koc can be calculated by using the log Kow. The calculation is based on linear regression and also includes correction factor coefficients.
Log Koc estimated ranges from 4.1 to 4.9.
- Endpoint:
- adsorption / desorption
- Remarks:
- adsorption
- Type of information:
- (Q)SAR
- Adequacy of study:
- weight of evidence
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: KOCWIN v2.00 - Model to estimate the soil adsorption coeffiecient (Koc) of organic compounds, v2.00, February 2009, US Environmental Protection Agency (2000-2008).
- Justification for type of information:
- QSAR prediction: migrated from IUCLID 5.6
- Reason / purpose for cross-reference:
- reference to same study
- Qualifier:
- no guideline required
- Principles of method if other than guideline:
- Estimation methods for predicting Koc values for hydrophobic organic compounds based upon the first-order molecular connectivity index (MCI).
- GLP compliance:
- no
- Computational methods:
- Molecular Connectivity Index:
The equation derived by the non-polar (no correction factor) regression is:
log Koc = 0.5213 MCI + 0.60
(n = 69, r2 = 0.967, std dev = 0.247, avg dev = 0.199)
Where MCI is the Molecular Connectivity Index.
Adding in the correction factor regression yields the final MCI equation:
log Koc = 0.5213 MCI + 0.60 + ΣPfN
where ΣPfN is the summation of the products of all applicable correction factor coefficients multiplied by the number of times (N) that factor is counted for the structure.
Reference: Meylan, W., P.H. Howard and R.S. Boethling. 1992. Molecular topology/fragment contribution method for predicting soil sorption coefficients. Environ. Sci. Technol. 26: 1560-1567. - Type:
- log Koc
- Value:
- 3.94
- Remarks on result:
- other: Calculation based on Molecular Connectivity Index with a correction factor for the ketone
- Transformation products:
- not measured
- Statistics:
- Linear regression, for details see Koc WIN model
- Validity criteria fulfilled:
- not applicable
- Conclusions:
- log Koc estimated from the Molecular Connectivity Index is 3.9.
- Executive summary:
The Koc can be calculated by utilizing a Molecular Connectivity Index. Log Koc estimated from the Molecular Connectivity Index is 5.07.
Referenceopen allclose all
If the log Kd-value is constant and independent of the AHTN concentration, the relation between log Csludge and log Ceffluent is a straight line with a slope of 45º. Based on the data and this assumption, the values for the 18 STPs in this study (including 3 plants from Berlin) for AHTN is log Kd = 3.96.
In fact a better curve fitting was achieved by AHTN: (Csludge)0.67= 5.35·Ceffluent.
This means that Kd is not really constant, but according to this data set, the value of Kd increases at higher concentrations in sludge, or in other words, the adsorptive power increases at higher concentrations.
Optimized values (± SEM) obtained from the regression analysis on the model.
Kbio, true(h-1) |
0.023 ± 0.010 |
kev (h-1) |
0.0085 ± 0.0002 |
log Koc |
3.1±0.2 |
Kbio, true: Rate constant microbial degradation
kev (h-1): Evaporation rate constant
Although AHTN is very hydrophobic, it is not completely non-polar due to the presence of a ketone. Hence, the following equations are used to calculate Koc on the basis of Log Kow.
Koc Estimate from Log Kow:
Log Kow varies from 5.4 to 5.7.
Log Koc = 0.55313·Log Kow + 0.9251.
The uncorrected Log Koc ranges from 3.91 to 4.08.
Correction factor for the ketone group is 0.1956
Corrected log Koc ranges from 4.11 - 4.27.
Estimated Koc:12810 - 18770L/kg.
Koc Estimate from Log Kow for non-polar molecules:
Log Kow varies from 5.4 to 5.7.
Log Koc = 0.8679·Log Kow - 0.0004.
Corrected log Koc ranges from 4.68 - 4.95.
Although AHTN is very hydrophobic, it is not completely non-polar due to the presence of a ketone. Hence, the following equations are used to calculate Koc on the basis of molecular connectivity and Log Kow.
Koc Estimate from Molecular Connectivity Index (MCI):
First Order Molecular Connectivity Index: MCI = 8.570
log Koc = 0.5213·MCI + 0.60 = 5.06 (uncorrected)
Correction factor for the ketone group is -1.1290
Corrected log Koc = 5.06 - 1.1290 = 3.94.
Estimated Koc:8678L/kg.
Description of key information
The Koc for the test item is found to be highly variable, depending on the environmental matrix and no single representative value was established. The estimated partition coefficient based on the EUSES QSAR for predominantly hydrophobics falls well within the range and has been selected.
Key value for chemical safety assessment
- Koc at 20 °C:
- 29 512
Additional information
The observed variability of log Kd-values in the study of Blok between 3.6 and 4.3 (extremes) is a factor of 5. Müller reported a log Kd ranging from 4.1 to 5.0. Doi reported a log Kd of 4.06. Koc is also observed to vary. The HPLC screening method used by Müller gives a log Koc of 3.41, while measurements in soil varied from 3.7 to 4.13. The EU Risk Assessment mentions values for log Koc of 3.1 to 4.8 in activated sludge.
The log Koc calculated on the basis of Log Kow were more in line with the experimental results. The EU Risk Assessment used the formula Log Koc = 0.81·log Kow + 0.1 (for predominantly hydrophobics) and a log Kow of 5.4 to obtain a log Koc of 4.47. Note that the log Kow of 5.7 (Rudio 1993) results in log Koc of 4.7. In the v2.00 version of KocWin, the new equation for the Koc calculation gives log Koc 4.9. The differences in the calculations are marginal, when considering the background of the wide distribution of Koc values measured in the environment. .
Empirical values of Kd and Koc vary considerably. All calculated values fall within the range of experimentally derived data and for the purpose of consistency, the calculated Koc based on the Kow (EUSES) as reported in the EU Risk Assessment Report of AHTN has been used.
Desorption test by Müller showed that adsorption is not reversible.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.