Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
ISO 13736 (Petroleum products and other liquids - Determination of flash point - Abel closed cup method)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Abel apparatus
Key result
Flash point:
35 °C
Atm. press.:
978.7 hPa
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The mean flash point flash point of test chemical was determined to be 35°C at 978.7 hPa.
Executive summary:

The flash point determination of test chemical was done following closed cup method using Abels flash point apparatus. The flash point was determined to be 35°C at 978.7 hPa.Hence the substance is considered to be category 3 flammable substance based on GHS criteria.

Description of key information

The flash point determination of test chemical was done following closed cup method using Abels flash point apparatus. The flash point was determined to be 35°C at978.7hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
35 °C

Additional information

The flash point determination of test chemical was done following closed cup method using Abels flash point apparatus. The flash point was determined to be 35°C at978.7hPa.

Hence the substance was considered to be category 3 flammable substance based on GHS criteria.