Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 601-490-4 | CAS number: 117704-25-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Phototransformation in water
Administrative data
Link to relevant study record(s)
- Endpoint:
- phototransformation in water
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- From 10 Nov 1993 to 02 May 1994
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Study run to a method comparable with current guidelines and to GLP.
- Study type:
- other: Photodegradation
- Qualifier:
- according to guideline
- Guideline:
- other: U.S. Food and Drug Administration, Environmental Assessment Technical Assistance Document 3.10, Photodegradation
- Deviations:
- no
- GLP compliance:
- yes
- Radiolabelling:
- yes
- Analytical method:
- high-performance liquid chromatography
- Details on sampling:
- - Sampling intervals for the parent/transformation products: 0, 6, 24, 48, and 72 hours for preliminary study and 0, 1, 2, 3, 3.5, 5, 6, 6.5, 7, 7.5, 8, and 24 hours for the definitive study
- Sampling intervals/times for pH measurements: at time 0 and at test completion
- Sampling intervals/times for sterility check: at time 0 and at test completion
- Sample storage conditions before analysis: transferred to amber bottles for storage (1-9℃) - Light source:
- Xenon lamp
- Light spectrum: wavelength in nm:
- 290 - 800
- Relative light intensity:
- 578
- Details on light source:
- The intensity of the xenon lamp during the study was 578 watts/m2 over the range 290 to 800 nm or 49.7 watts/m2 over the UV range 290 to 385 nm.
- Details on test conditions:
- Test solution preparation:
Since the test article was not very soluble in water (25±5.2 μg/L at 25 ℃), the stock solution of the test article was provided as a water, methanol, and acetonitrile mixture by the Sponsor at a concentration of 0.8 mg/mL. The concentration of the test article required for the study was 1 ppm which was equivalent to 1.28 mL of 14C-test substance stock solution in 1000 mL of water. A working stock solution was prepared by adding 896 μL of the original stock solution 7.104 mL ACN. The test solution of 14C-test substance was prepared by adding an aliquot (7 mL) of the working stock solution aseptically to a 1000 mL volumetric flask were mixed thoroughly by inverting and shaking. The final concentration of the test solution was approximately 1 ppm (~ 0.7 mg test article in 700 mL Millipore water).
Test system:
In the definitive study, three quartz test vessels (two for 14C-test substance and one for actinometer) containing approximately 150 mL of test solution were placed in a Hereaus Suntest system equipped with a xenon lamp.
Concurrently, three quartz test vessels (two for 14C-test substance and one for actinometer) containing approximately 150 mL test solution were wrapped in aluminum fail and were placed in an incubator in the dark at 25.0 ± 2.0 ℃. - Duration:
- 24 h
- Temp.:
- 25 °C
- Initial conc. measured:
- 1 mg/L
- Reference substance:
- yes
- Remarks:
- p-nitro acetophenone-pyridine
- Dark controls:
- yes
- Preliminary study:
- Approximately 43-54% of 14C-test substance was degraded in irradiated samples in 6 hours. In 24 hours, 100% of 14C-test substance was degraded under simulated sunlight. Dark controls (0 hours and 24 hours) and the samples designated for irradiation at 0 hour showed that 14C-test substance was intact.
- Parameter:
- max lambda
- Value:
- 244 nm
- % Degr.:
- 59
- Sampling time:
- 5 h
- Test condition:
- Irradiating
- % Degr.:
- 100
- Sampling time:
- 24 h
- Test condition:
- Irradiating
- Rate constant (for indirect photolysis):
- 0.16 other: hour-1
- DT50:
- 4.45 h
- Test condition:
- ~ 1 ppm solution of 14C-test substance continuously exposed to simulated sunlight
- Transformation products:
- not specified
- Details on results:
- The major photoproducts were polar materials that eluted close to the void volume of the isocratic HPLC method. Using an alternate HPLC method with gradient elution, the polar peak was resolved into at least six components (by UV detection at 244 nm) that eluted between 2.0 to 5.0 minutes and collectively accounted for 11% of the detected radioactivity. Although no major UV peaks were detected between 5 and 35 minutes, peaks detected by radioscan during this time period accounted for 28% of the detected radioactivity. The low UV response of radiolabel photoproducts implied these compounds did not contain the macrolide ring chromophore characteristic of test substance. From the combination of the UV and 14C radiochromatograms, the region between 0 and 45 minutes contained at least 10 components, none of which accounted for more than 10% of the applied radioactivity. Therefore, minor photodegradates were not further characterized. No degradation was observed in the 14C test substance or in the actinometer dark controls. The absence of absorption of light in the 290-800 nm range by test substance, as demonstrated by its UV-VIS absorption, suggested that 14C test substance was photodegraded by indirect mechanisms rather than by a direct absorption of photons.
- Results with reference substance:
- The dark controls (0 and 24 hours) and samples designated for irradiation at 0 hour showed that actinometer was intact. However, at the 5 hour sampling interval, a decrease in p-nitro acetophenone in irradiated samples was observed compared to 5-hour dark control. Approximately 27% of the actinometer was photodegraded in 5 hours. Furthermore, at the 24 hour sample interval, decrease of p-nitro acetophenone in irradiated samples was pronounced compared to the 5 hour irradiated sample. The degradation was 79% within 24 hours of irradiation.
- Validity criteria fulfilled:
- yes
- Conclusions:
- The test article 14C-test substance degraded rapidly under simulated sunlight with a half-life of 4.45 hours.
Reference
Description of key information
The test article 14C-test substance degraded rapidly under simulated sunlight with a half-life of 4.45 hours.
Key value for chemical safety assessment
- Half-life in water:
- 4.45 h
Additional information
A Photodegradation study was conducted according to FDA Environmental Assessment Technical Assistance Document 3.10 under GLP (Fernando, 1994). The test article 14C-test substance degraded rapidly under simulated sunlight with a half-life of 4.45 hours.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.