Administrative data

Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 122 (Determination of pH, Acidity and Alkalinity)
Version / remarks:
2013
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
4-acetyl-2-methylbenzoic acid
EC Number:
856-079-4
Cas Number:
55860-35-0
Molecular formula:
C10H10O3
IUPAC Name:
4-acetyl-2-methylbenzoic acid
Test material form:
solid: particulate/powder

Reagents

Reagent:
water

Results and discussion

pH value
Key result
pH value:
2.85
Temp.:
20 °C
Concentration:
1 vol%

Applicant's summary and conclusion

Conclusions:
The pH value of a 1% w/v aqueous dispersion of the substance has been determined to be 2.85 at 20 °C.
Executive summary:

The pH value of the substance in water was determined under GLP to OECD TG 122. Two independent measurements were performed. An aliquot of test substance (about 1 g) was added to 50 mL of high puritywater. Each sample was then diluted to 100 mL with high purity water before being shaken vigorously for one minute. The high purity water, with a specification of resistance >18.2 MΩ and TOC <5 ppb, was pre-equilibrated to 20 °C before use. Each sample was then transferred to a sample cup, allowed to settle for a period of 1 minute and the pH value then determined. The pH value was recorded from the pH meter, without stirring of the sample, after a period of 1 minute equilibration and a second reading was recorded after a period of 2 minutes equilibration. If the difference between the two readings did not exceed 0.1 pH units, the pH value was considered stable. If a pH drift greater than 0.1 pH units was observed between the two readings, a final pH value reading was taken after 10 minutes equilibration.