Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no

Test material

Constituent 1
Reference substance name:
-
EC Number:
416-390-4
EC Name:
-
IUPAC Name:
Blend of Magneli suboxides of titanium
Details on test material:
Ebonex® Powder, Batch Composite 01, Composition: 2% Ti3O5, 49% Ti4O7, 36% Ti5O9, 5% Ti6O11, 7% Ti7O13, 1% Ti8O15. The Ebonex Powder used in this experiment differed from the Substance listed in Section 1 in that it contained less Ti4O7 and Ti6O11 and more Ti5O9. It also contained small proportions of Ti3O5, Ti7O13 and Ti8O15. However, the Ebonex Powder used for this study was still a blend of Magneli suboxides of titanium, primarily based upon the same three titanium oxides, Ti4O7, Ti5O9 and Ti6O11 as in the current Ebonex Powder listed in Section 1. As such the results from the Ebonex Powder used in this experiment are considered to be applicable for the current Ebonex Powder as listed in Section 1.

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: Not considered as highly flammable
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

This material did not ignite and propagate combustion eother by burning with flame or smouldering along 200mm of the powder train within the four minutes (or 40 minutes) test period , the substance should not be considered as highly flammable.

Applicant's summary and conclusion