Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 241-221-4 | CAS number: 17169-60-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Particle size distribution (Granulometry)
Administrative data
Link to relevant study record(s)
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2020-04-07
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- study well documented, meets generally accepted scientific principles, acceptable for assessment
- Qualifier:
- no guideline followed
- Principles of method if other than guideline:
- - Principle of test:
100 g of the substance were weighed. After this, the weight was put in an analytical sieve machine and sieved under controlled electromagnetic drive for 2 min.
- Short description of test conditions:
Equipment
- Verified scale
- Analytical Sieve machine Retsch AS200 control
- 900 µm sieve
- 800 µm sieve
- 600 µm sieve
- 500 µm sieve
- 400 µm sieve
- 300 µm sieve
- 200 µm sieve
- 100 µm sieve
Parameters
- Amplitude 1,02 mm (lifting height)
- Sieving for 2 min
- Interval off
- Parameters analysed / observed: mass based distribution - GLP compliance:
- no
- Other quality assurance:
- other: The undersigned head of Quality Management as part of qualified and specialized personnel of the Senso additive GmbH confirms that the sieve analysis described in this report was carried out to the best of their knowledge.
- Type of method:
- sieving
- Type of particle tested:
- primary particle
- Type of distribution:
- mass based distribution
- Key result
- Percentile:
- other: % of material initially placed on the sieve
- Mean:
- 0 other: %
- Remarks on result:
- other: 0% of the material was sieved at sizes of 900 - 500 µm
- Key result
- Percentile:
- other: % of material initially placed on the sieve
- Mean:
- 19.5 other: %
- Remarks on result:
- other: 19.5% of the material initially placed on the sieve was detected at sizes between 500 - 400 µm
- Key result
- Percentile:
- other: % of the material initially plaecd on the sieve
- Mean:
- 36.5 other: %
- Remarks on result:
- other: 36.5% of the material initially placed on the sieve was detected at sizes between 400 - 300 µm
- Key result
- Percentile:
- other: % of the material initially placed on the sieve
- Mean:
- 37.5 other: %
- Remarks on result:
- other: 37.5% of the material initially placed on the sieve was detected at sizes between 300 - 200 µm
- Key result
- Percentile:
- other: % of the material initially placed on the sieve
- Mean:
- 6.5 other: %
- Remarks on result:
- other: 6.5% of the material initially placed on the sieve was detected at sizes between 200 - 100 µm
- Key result
- Percentile:
- other: % of the material initially placed on the sieve
- Mean:
- 0 other: %
- Remarks on result:
- other: 0% of the material initially placed on the sieve was detected at sizes between < 100 µm
- No.:
- #1
- Size:
- >= 500 - <= 900 µm
- Distribution:
- 0 %
- No.:
- #2
- Size:
- >= 400 - <= 500 µm
- Distribution:
- 19.5 %
- No.:
- #3
- Size:
- >= 300 - <= 400 µm
- Distribution:
- 36.5 %
- No.:
- #4
- Size:
- >= 200 - <= 300 µm
- Distribution:
- 37.5 %
- No.:
- #5
- Size:
- >= 100 - <= 200 µm
- Distribution:
- 6.5 %
- No.:
- #6
- Size:
- < 100 µm
- Distribution:
- 0 %
- Conclusions:
- Based on the present test conducted to determine the particles size of the test substance by sieving the substance contains only particles that are between 500 and 100 µm in size. No particles under 100 µm size were detected.
- Executive summary:
The particle size of ferrous monoglycinate sulfate was determined by sieving the substance with an analytical sieve machine containing different sizes of sieves. No Particles were found below a size of 100 µm.
Reference
Description of key information
Based on the present test conducted to determine the particles size of the test substance by sieving the substance contains only particles that are between 500 and 100 µm in size. No particles under 100 µm size were detected.
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.