Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
fron 5 to 8 dec 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: vapour pressure balance
Specific details on test material used for the study:
Identity: Semicarbazide Hydrochloride
Appearance: White solid
Storage conditions: Room temperature (15 to 25°C), dark
Batch number: 55507861
Purity: 99.3%
Expiry date: 28 April 2019
Date received: 28 April 2017
Key result
Test no.:
#1
Temp.:
ca. 25 °C
Vapour pressure:
ca. 0 Pa

None

Conclusions:
The vapour pressure of Semicarbazide Hydrochloride was found to be 3 x 10-4 Pa at 25ºC.
Executive summary:

The purpose of this study was to determine the vapour pressure of the test item, Semicarbazide Hydrochloride.

The study was conducted in accordance with accepted principles in order to meet the requirements of REACH Regulation (EU) No 1907/2006 of the European Parliament and of the Council, REACH Regulation (EC) No 440/2008 (as amended) of 30 May 2008 (Method A.4) and the OECD Guidelines for Testing of Chemicals (Method 104).

The vapour pressure of Semicarbazide Hydrochloride was found to be 3 x 10-4 Pa at 25ºC.

Description of key information

The purpose of this study was to determine the vapour pressure of the test item, Semicarbazide Hydrochloride.

The study was conducted in accordance with accepted principles in order to meet the requirements of REACH Regulation (EU) No 1907/2006 of the European Parliament and of the Council, REACH Regulation (EC) No 440/2008 (as amended) of 30 May 2008 (Method A.4) and the OECD Guidelines for Testing of Chemicals (Method 104).

The vapour pressure of Semicarbazide Hydrochloride was found to be 3 x 10-4 Pa at 25ºC.

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
25 °C

Additional information