Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
yes
Remarks:
An abiotic Control for the reference item was performed during this study although it was not planned in the study plan.
GLP compliance:
yes
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Batch 20180329 (Source Lead)
- Expiration date of the lot/batch: March 2019
- Purity test date: March 2018

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: romm temperature 20 +/-10°C
- Stability under test conditions: stable
- Solubility in water : 0.19 to 0.26 g/L
Analytical monitoring:
no
Vehicle:
yes
Details on test solutions:
PREPARATION AND APPLICATION OF TEST SOLUTION:
- Method: directly diluted
- Controls: Yes
- Chemical name of vehicle : osmosed water
- Concentration of vehicle in test medium : 10 - 40 - 160 - 640 and 2560 mg/L
- Evidence of undissolved material: the test item is poorly soluble in water
Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
- Laboratory culture: FCBA
- Name and location of sewage treatment plant where inoculum was collected: STEP de Lille, 33290 BLANQUEFORT - FRANCE
- Method of cultivation: A filtration through a fine sieve (around 1 mm) was performed in order to remove coarse particles. After removal of any coarse particles, the sludge was washed by decantation in osmosed water and test medium ( 50/50 (v/v) to adjust concentration of dry extract around 3 g/L. The activated sludge was continuously aerated until usage in the test and fed daily with 50 mL/L synthetic sewage feed for one or two additional days.
- Test medium : mineral mediium (Na2HPO4, 2H2O, K2HPO4, NH4Cl, KH2PO4, CCl2, 2H2O, MGSO4, 7H2O, FeCl3, 6H20)
- Initial biomass concentration: 1.45 g suspended solids/L in this test
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 d
Hardness:
No data
Test temperature:
20 +/-2°C
pH:
End of the test : 8.2 to 8.6
Salinity:
Not relevant
Conductivity:
Not relevant
Nominal and measured concentrations:
Nominal : 10 - 40 - 160 - 640 and 2560 mg/L
Details on test conditions:
The test was carried out into 1000 mL glass flasks containing 500 mL as below:
- 16.0 ml synthetic sewage feed (Peptone, Meat Extract, Ura, NCl, CaCl2-2H2O, MgSO4-7H20, K2HPO4, ultrapure water)
- Adequate weighing of test item
- osmosed water (final volume: 500 mL)
- 250 mL of sludge suspension

Replicates: Six replicates for controls (Control a to Control f)
Two replicates for abiotic controls
Three replicates (a, b and c) per treatment (1 to 5) for the test item
One replicate per treatment for the reference item (3,5 DCP)

The concentrations for the 3,5 DCP were : 0.5 – 1.6 – 5.1 – 16.40 and 52.4 mg/L

At the start of the test, the first control (Control a) was prepared and covered with parafilm. Then every 10 -15 minutes the others flasks were prepared in turn in the same conditions. Finally, the last control (Control f) was prepared.
All suspensions were aerated with purified air (0.5 to 1 L/min), and stirred during 3 hours at 20 ± 2°C. Then, each suspension was poured into Karlsruher flask (following the order preparation). The Oxygen was measured every minute, during 10 minutes, with a Dissolved Oxygen Sensor (WTW StirrOx G) integrated Stirrer, inserted into the Karlsruher flask

EFFECT PARAMETERS MEASURED : Activated sludge respiration inhibition, measured as oxygen consumption rate (dissolved oxygen concentration)
Reference substance (positive control):
yes
Remarks:
3,5 dichlorophenol
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 43.2 - < 296.6 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Key result
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
ca. 165.4 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Duration:
3 h
Dose descriptor:
NOEC
Effect conc.:
ca. 10 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Duration:
3 h
Dose descriptor:
LOEC
Effect conc.:
ca. 40 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Details on results:
-
Results with reference substance (positive control):
- Results with reference substance valid : Yes
- Relevant effects levels : EC50 : 13.7 mg/L ; oxygen uptake in the control : 38.8 mg O2/ g sludge/h ; Coefficient of varation of O2 : 0.0 to 14.6%

  O2 consumption and inhibition

Treatment

Name

O2consumption in

mg O2/(L*h)

% inhibition

pH (end of the test)

Inoculum Control

Control a

51.00

/

8.4

Control b

52.50

/

8.4

Control c

61.50

/

8.3

Control d

60.00

/

8.2

Control e

57.60

/

8.2

Control f

55.20

/

8.3

Abiotic Control reference item

Abiotic Control 3,5 DCP

/

/

7.0

Reference Item

3,5 DCP Conc 1

55.5

1.42

8.3

3,5 DCP Conc 2

54.0

4.09

8.4

3,5 DCP Conc 3

48.0

14.74

8.4

3,5 DCP Conc 4

22.7

59.68

8.4

3,5 DCP Conc 5

7.5

85.79

8.4

Abiotic Control Test item

Abiotic Control Test item a

/

/

7.0

Test Item

1a

62.00

- 10.1

8.2

1b

62.00

- 10.1

8.2

1c

54.00

4.1

8.3

2a

42.00

25.4

8.3

2b

43.00

23.6

8.3

2c

36.00

36.1

8.4

3a

8.00

85.8

8.4

3b

3.43

93.9

8.5

3c

3.33

94.1

8.4

4a

0.00

100.0

8.6

4b

0.67

98.8

8.6

4c

0.00

100.0

8.6

5a

0.67

98.8

8.6

5b

0.00

100.0

8.6

5c

0.67

98.8

8.6

Abiotic Test item

Abiotic Test item b

/

/

7.0

Validity criteria fulfilled:
yes
Conclusions:
This study was performed using five concentrations, ranging from 10 to 2560 mg/L nominal concentrations. The dry matter of the activated sludge was determined as 2.9 g suspended solids/L, giving a concentration of 1.45 g suspended solids/L in this test. The validity criteria for OECD 209 were successful. And the nominal concentrations of 4-PhenoxyPhenol are :
- CE50-3h = 165.4 mg/L [43.2 - 296.6]
- NOEC = 10 mg/L
- LOEC = 40 mg/L
Executive summary:

An OECD 209 was performed on 4 -PhenoxyPhenol using five concentrations, ranging from 10 to 2560 mg/L nominal concentrations. The dry matter of the activated sludge was determined as 2.9 g suspended solids/L, giving a concentration of 1.45 g suspended solids/L in this test. The validity criteria for OECD 209 were successful. And the nominal concentrations of 4-PhenoxyPhenol are :

  • CE50-3h = 165.4 mg/L [43.2 - 296.6]
  • NOEC = 10 mg/L
  • LOEC = 40 mg/L

Description of key information

An OECD 209 was performed on 4 -PhenoxyPhenol using five concentrations, ranging from 10 to 2560 mg/L nominal concentrations. The dry matter of the activated sludge was determined as 2.9 g suspended solids/L, giving a concentration of 1.45 g suspended solids/L in this test. The validity criteria for OECD 209 were successful. And the nominal concentrations of 4-PhenoxyPhenol are :

  • CE50-3h = 165.4 mg/L [43.2 - 296.6]
  • NOEC = 10 mg/L
  • LOEC = 40 mg/L

Key value for chemical safety assessment

EC50 for microorganisms:
165.4 mg/L
EC10 or NOEC for microorganisms:
10 mg/L

Additional information