Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 Aug 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Ministerium für Umwelt und Naturschutz, Landwirtschaft und Verbraucherschutz des Landes Nordrhein-Westfalen
Analytical monitoring:
no
Vehicle:
no
Details on test solutions:
PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)
- Method: Direct weighting
- Differential loading: yes
- Controls: blank control
- Eluate: no
Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
- Laboratory culture: no
- Name and location of sewage treatment plant where inoculum was collected: STP, Cologne-Stammheim, Germany (aeration tank)
- Method of cultivation: Aeration of the activated sludge at 20 °C ± 2 °C, daily feed with synthetic medium.
- Preparation of inoculum for exposure: First, the sludge is settled and supernatant is decanted. After centrifuging (15 min at 4000 rpm and 20°C) the supernatant is decanted again. 1 g of wet sludge is dried in order to calculate the amount of wet sludge to achieve a concentration of activated sludge of 3 g/L (dry wet) suspended solids. The calculated amount of sludge is first dissolved in synthetic medium and then filled up to a defined end volume with de-ionized water.
- Pretreatment: none
- Concentration of Inoculum: 3 g/L (dry weight).
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Test temperature:
20.7 - 20.9 °C
pH:
7.7 - 7.9
Dissolved oxygen:
See "Any other information on results incl. tables"
Nominal and measured concentrations:
nominal: control, 10, 18, 32, 56 and 100 mg/L
Details on test conditions:
TEST SYSTEM
- Test vessel: 300 mL glass Erlenmeyer flasks
- Aeration: yes
- No. of vessels per concentration (replicates): 1
- No. of vessels per control (replicates): 2
- Sludge concentration (weight of dry solids per volume): 800 mg/L suspended solids

TEST MEDIUM / WATER PARAMETERS
- Preparation of test medium: according to guideline

OTHER TEST CONDITIONS
- Adjustment of pH: yes, adjusted to pH 7±0.5 using HCl

EFFECT PARAMETERS MEASURED: respiration inhibition after 3 h of incubation

TEST CONCENTRATIONS
- Range-finding test : 10, 100 and 1000 mg/L
- Results used to determine the conditions for the definitive study: The range-finding test revealed inhibition rates of 20.1%, 74.2% and 100% for test substances concentrations of 10, 10 and 100 mg/L, respectively.
Reference substance (positive control):
yes
Remarks:
3,5-Dichlorophenol
Duration:
3 h
Dose descriptor:
EC10
Effect conc.:
5.7 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
other: respiration rate
Remarks:
95% CL: 1.6 - 10.2 mg/L
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
41.4 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
other: respiration rate
Remarks:
95% CL: 30.8 - 58.7 mg/L
Details on results:
- Effect concentrations exceeding solubility of substance in test medium: no
- Blank controls oxygen uptake rate: no physico-chemical oxygen consumption was observed
Results with reference substance (positive control):
- Results with reference substance valid? yes, the EC50 of 3,5-dichlorophenol is in the accepted range 5 to 30 mg/L
- EC50 (3 h): 7.2 mg/L (95% CI: 3.8 - 13.2 mg/L)
Reported statistics and error estimates:
Inhibitory effect of the test item: Percentage of the mean of the respiration rates of two controls. EC50 values: Determined by probit analysis of the respiration rates at different test substance concentrations.

Table 1: Main test (test substance CMK): Oxygen content, temperature and pH values during exposure phase

 

Test item concen-tration [mg/L]

O2 start [mg O2/L]

O2 end [mg O2/L]

Time (start-end) [min.]

Temp.

[°C]

pH

Test item

10

5.7

2.6

7

20.6

7.7

18

5.5

2.8

7

20.5

7.7

32

5.8

2.7

9

20.7

7.7

56

5.9

3.9

8

20.8

7.6

100

6.2

5.0

9

20.9

7.5

Control 1

 

5.7

2.8

5

21.1

7.7

Control 2

 

5.4

2.7

5

20.6

7.7

Physico-chemical oxygen consumption control *

 

7.5

7.5

9

20.8

7.3

  Comments: * Data obtained in the range finding test. The test item was added to about 130 mL deionized water and stirred overnight before testing (equilibration phase).

Table 2: Results of test item

Test item concen-tration [mg/L]

Respiratory ratetest item [mg/L h]

Phys.-chem. O2 consumption [mg/Lh]

Respiratory rate - phys.-chem. O2 consumption [mg/Lh]

Inhibition [%]

10

26.6

0.0*

26.6

20.9

18

23.1

0.0*

23.1

31.1

32

20.7

0.0*

20.7

38.5

56

15.0

0.0*

15.0

55.4

100

8.0

0.0

8.0

76.2

Control. Mean

33.6

 

Control 1

34.8

 

Control 2

32.4

 

* The physico-chemical oxygen consumption has been determined at 1000 mg/L test item concentration. As no physico-chemical oxygen consumption was observed at that test item concentration this observation also holds true for the lower test item concentrations.

Table 3: Validity criteria

Criterion from the guideline

Outcome

Validity criterion fulfilled

The two control respiration rates are within 15 per cent of each other.

Respiratory rates of the 2 controls differ less than 15 %

yes

The EC 50 (3 hours) of 3,5-dichlorophenol is in the accepted range 5 to 30 mg/L.

EC50 of the reference compound 3.5-Dichlorophenol is in the range 5 – 30 mg/L

yes

Validity criteria fulfilled:
yes
Remarks:
For further details please refer to “Any other information on results incl. tables”.
Conclusions:
EC 50 (3 h) = 41.4 mg/L
EC 10 (3 h) = 5.7 mg/L
Executive summary:

The effect of p-chloro-m-cresol on aquatic micro-organism was investigated by Neuhahn (2008) in accordance with the OECD guideline 209 and EC Method C.11. P-chloro-m-cresol showed inhibitory effects on activated sludge. 50% inhibition of microbial activity was determined at 41.4 mg/L. The EC10 was determimed at 5.7 mg/L.

Endpoint:
activated sludge respiration inhibition testing
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Justification for type of information:
Refer to analogue justification document provided in IUCLID section 13.
Duration:
3 h
Dose descriptor:
EC10
Effect conc.:
5.7 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
other: respiration rate
Remarks:
95% CL: 1.6 - 10.2 mg/L
Remarks on result:
other:
Remarks:
source, CAS 59-50-7, key rel 1, Neuhahn 2008
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
41.4 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
other: respiration rate
Remarks:
95% CL: 30.8 - 58.7 mg/L
Remarks on result:
other:
Remarks:
source, CAS 59-50-7, key rel 1, Neuhahn 2008

Description of key information

EC50 (3 h) = 41.4 mg/L (nominal, activated sludge microorganisms), read-across

EC10 (3 h) = 5.7 mg/L (nominal, activated sludge microorganisms), read-across

Key value for chemical safety assessment

EC50 for microorganisms:
41.4 mg/L
EC10 or NOEC for microorganisms:
5.7 mg/L

Additional information

No study investigating the toxicity of sodium p-chloro-m-cresolate (CAS 15733-22-9) to aquatic microorganisms is available. Therefore, in accordance to Regulation (EC) No. 1907/2006 Annex XI, 1.5 a read-across to the source substance (p-chloro-m-cresol, CAS 59-50-7) which is the main transformation product of the target substance sodium p-chloro-m-cresolate (CAS 15733-22-9) is applied.

The source substance p-chloro-m-cresol is the common compound in this analogue approach and is solely responsible for the (absence of) effects. Thus, the source substance is considered a suitable representative for the evaluation of the toxicity of the target substance to aquatic organisms. The read-across approach is justified in detail within the analogue justification in IUCLID section 13.

One experimental study is available investigating the effect of p-chloro-m-cresol on aquatic microorganism (Neuhahn, 2008). The test was conducted according to OECD guideline 209 and EC Method C.11. Activated sludge microorganisms were exposed for 3 hours to nominal concentrations of 10, 18, 32, 56 and 100 mg/L. The inhibition of respiration was measured at the end of the study. P-chloro-m-cresol showed inhibitory effects on activated sludge microorganisms. 50% inhibition of microbial activity was determined at 41.4 mg/L. Therefore the EC50 (3 h) was 41.4 mg/L. The EC10 (3 h) was determined to be 5.7 mg/L.

Based on the available results from a structurally similar source substance (in accordance to Regulation (EC) No 1907/2006 Annex XI, 1.5) which is the main transformation product of the target substance and is characterized by a similar ecotoxicological profile and comparable structure, it can be concluded that sodium p-chloro-m-cresolate has effects in the same range as the target substance.