Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 September 2015 - 19 January 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: UN no. ST/SG/AC/Rev.5: Recommendations on the Transport of Dangerous Goods, Part III, Test N.1: "Test Method for Readily Combust
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
p-fluorophenyl 4-piperidyl ketone hydrochloride
EC Number:
247-070-0
EC Name:
p-fluorophenyl 4-piperidyl ketone hydrochloride
Cas Number:
25519-78-2
Molecular formula:
C12H14FNO.ClH
IUPAC Name:
4-(4-fluorobenzoyl)piperidine hydrochloride
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
- Name of test material (as cited in study report): JNJ-398099-AAC (T001047)
- Physical state: solid powder
- Appearance: white powder
- Batch n°: I15DB1484
- Analytical purity: 97.2%
- Expiration date: 19 April 2017
- Storage condition: 15-25°C

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Any other information on results incl. tables

The flame of the gas burner did ignite the test item pile. The test item melted, burned with a blue yellow flame and turned into a black residue. Black smoke was observed. After removal of the ignition source, the flame extinguished immediately and no propagation of combustion was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not readily combustible’ (i.e. ‘not flammable’).

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The preliminary screening test was performed for the determination of the flammability of JNJ-398099-AAC (T001047).

No propagation of combustion of the test item along 200 mm length of the pile within 2 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not flammable’ or 'not readily combustible'.