Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
density, other
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
4th May 2000
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Limited details on methods, GLP and purity. Guideline study.
Qualifier:
according to guideline
Guideline:
other: ISO 2811-3/DIN 53217 part 5
Deviations:
not specified
Principles of method if other than guideline:
Limited details on method.
GLP compliance:
not specified
Type of method:
oscillating densitimeter
Key result
Type:
density
Density:
1.2 other: g/mL
Temp.:
20 °C

The density of the test material is given as 1.198 g/mL at 20 °C.

Conclusions:
The density of the test material is given as 1.198 g/ml at 20 °C.
Executive summary:

In a density test (Acima report No: AL 993A) the density of the test material is given as 1.198 g/ml at 20 °C.

The method was carried out according to ISO 2811 -3 / DIN 53217 Part 5.

Description of key information

In a density test (Acima report No: AL 993A) the density of the test material is given as 1.198 g/ml at 20 °C.

The method was carried out according to ISO 2811 -3 / DIN 53217 Part 5.

Key value for chemical safety assessment

Relative density at 20C:
1.19

Additional information

The key study selected for this endpoint, Maier D (2000) was performed to the guideline ISO 2811-3/DIN 53217 part 5, and supported by two further data sources which concur with the conclusions of the report. A reliability rating of 2 was assigned to this study, according to the criteria of Klimisch, 1997.

Supporting information is also available from a test material safety data sheet, Atofina Chemicals Inc. (2001).

A reliability rating of 4 was assigned to this study, according to the criteria of Klimisch, 1997 as this information is from a secondary source.

Results: The relative density for the test material is given as 1.1863.

For the ATSDR (2005) report a reliability rating of 4 was assigned to this study, according to the criteria of Klimisch, 1997 as this information is from a secondary source.

Results: The density for the test material is given as 1.20 g/cm3.