Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO No., other: OECD Method ASTM D93
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point:
> 110 °C
Atm. press.:
756 mm Hg
Remarks on result:
other: Room temperature: 20°C
Conclusions:
The flash point is determined above 110°C at 756 mmHg.
Executive summary:

Flash point has been measured by closed cup method according to OECD Method ASTM D93.

In the test conditions, flash point of CAS number 1227096 -04 -9 is above 110°C at 756 mmHg.

Even if determination has been run without GLP compliance, this study follows EU and OECD guidelines. Therefore, this study is considered as reliable with restrictions.

Description of key information

The flash point of the substance is above 110°C at 756 mmHg.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
110 °C

Additional information