Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 249-268-2 | CAS number: 28855-17-6
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Description of first aid measures
General advice : Move out of dangerous area.
Consult a physician.
Show this safety data sheet to the doctor in attendance.
If inhaled : Move to fresh air.
Consult a physician after significant exposure.
In case of skin contact : Take off contaminated clothing and shoes immediately.
Wash off with soap and plenty of water.
Immediate medical treatment is necessary as untreated
wounds from corrosion of the skin heal slowly and with
difficulty.
In case of burns apply cold water until pain subsides then
seek medical advice.
In case of eye contact : Small amounts splashed into eyes can cause irreversible
tissue damage and blindness.
In the case of contact with eyes, rinse immediately with plenty
of water and seek medical advice.
Continue rinsing eyes during transport to hospital.
Remove contact lenses.
Protect unharmed eye.
Keep eye wide open while rinsing.
If swallowed : Clean mouth with water and drink afterwards plenty of water.
Do NOT induce vomiting.
Do not give milk or alcoholic beverages.
Never give anything by mouth to an unconscious person.
Take victim immediately to hospital.
Fire-fighting measures
Extinguishing media
Suitable extinguishing
media
: Use water fog, foam, dry chemical or carbon dioxide (CO2) to
extinguish flames
Special hazards arising from the substance or mixture
Combustibility : Not classified as flammable or combustible, but will combust if
ignited.
Hazardous combustion
products
: Carbon monoxide, carbon dioxide and unburned
hydrocarbons (smoke).
Flammable properties :
See Section 9 for information on flammability.
Advice for firefighters
Protective equipment and
precautions for firefighters
: In the event of fire, wear self-contained breathing apparatus.
Fire Fighting Instructions : Collect contaminated fire extinguishing water separately. This
must not be discharged into drains.
Fire residues and contaminated fire extinguishing water must
be disposed of in accordance with local regulations.
Accidental release measures
Personal precautions,
protective equipment and
emergency procedures
: Avoid contact with spilled material. Do not touch or walk
through spilled material.
Use personal protective equipment.
Ensure adequate ventilation.
Evacuate personnel to safe areas.
Environmental precautions : Prevent entry into waterways, sewers, basements or
confined areas.
Do not flush into surface water or sanitary sewer system.
If the product contaminates rivers and lakes or drains inform
respective authorities.
Methods and materials for : Prevent further leakage or spillage if safe to do so.
containment and cleaning
up
Large Spills: Dyke far ahead of liquid spill for later recovery
and disposal.
Recover by pumping or with suitable absorbent
Report spills as required to appropriate authorities.
Seek the advice of a specialist before using dispersants.
Dispose of according to local regulations.
In the event of a spill or accidental release, notify relevant
authorities in accordance with all applicable regulations.
Material will float on water, use containment booms as a
barrier to protect shorelines.
Soak up with inert absorbent material (e.g. sand, silica gel,
acid binder, universal binder, sawdust).
Keep in suitable, closed containers for disposal.
Reference to other sections
Other information : For personal protection see section 8.
Handling and storage
Precautions for safe handling
Smoking, eating and drinking should be prohibited in the application area.
To avoid spills during handling keep bottle on a metal tray.
Dispose of rinse water in accordance with local and national regulations.
Normal measures for preventive fire protection.
Products may load from Infineum manufacturing site above the standard loading/unloading range.
Loading/unloading
temperature
: 40 °C (104 ° F) - 65 °C (149 ° F)
Viscosity @
Loading/unloading
temperature
: 410 cSt - 1.800 cSt
Static accumulator : This material is not a static accumulator.
Conditions for safe storage, including any incompatibilities
Keep container tightly closed in a dry and well-ventilated place.
Containers which are opened must be carefully resealed and kept upright to prevent leakage.
No decomposition if stored and applied as directed.
Do not reheat above: 65 °C (149 ° F)
Storage temperature : 50 °C (122 ° F) - 65 °C (149 ° F)
Incompatible materials and
coatings
: Inorganic Zinc
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- UN2586
Shipping information
- Proper shipping name and description:
- ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid - Chemical name:
- ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid - Language:
- English
- Labels:
- 8
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- UN2586
Shipping information
- Proper shipping name and description:
- ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid - Chemical name:
- ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid - Language:
- English
- Labels:
- 8
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- UN2586
Shipping information
- Proper shipping name and description:
- ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid - Chemical name:
- ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid
- EmS code:
- F-A
- Labels:
- 8
Special provisions / remarks
- Remarks:
- EmS Number 2 - S-B
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- UN2586
Shipping information
- Proper shipping name and description:
- ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid - Chemical name:
- ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid
- Labels:
- 8
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid
Hygiene measures : Handle in accordance with good industrial hygiene and safety
practice.
Wash hands before breaks and at the end of workday.
Environmental exposure controls
General advice : Prevent entry into waterways, sewers, basements or confined
areas.
: Do not flush into surface water or sanitary sewer system.
If the product contaminates rivers and lakes or drains inform
respective authorities.
Stability and reactivity
Reactivity
Chemical stability /
Possibility of hazardous
reactions
: Stable under normal conditions.
Conditions to avoid : Elevated temperatures. Excessive heat.
Incompatible materials : Strong oxidizing agents
Disposal considerations
Disposal recommendations based on material as supplied, Disposal must be in accordance with
applicable laws and regulations, and material characteristics at time of disposal
For the safety of persons conducting disposal, recycling or reclamation activities, refer to the
information in Section 8, Exposure control and personal protection.
Waste treatment methods
Product : The product should not be allowed to enter drains, water
courses or the soil.
Do not contaminate ponds, waterways or ditches with
chemical or used container.
Offer surplus and non-recyclable solutions to a licensed
disposal company.
Empty containers.
Empty Container Warning (where applicable): Empty containers may contain residue and can be
dangerous. Do not attempt to refill or clean containers without proper instructions. Empty drums
should be completely drained and safely stored until appropriately reconditioned or disposed.
Empty containers should be taken for recycling, recovery, or disposal through suitably qualified or
licensed contractor and in accordance with governmental regulations. DO NOT PRESSURISE,
CUT, WELD, BRAZE, SOLDER, DRILL, GRIND, OR EXPOSE SUCH CONTAINERS TO HEAT,
FLAME, SPARKS, STATIC ELECTRICITY, OR OTHER SOURCES OF IGNITION. THEY MAY
EXPLODE AND CAUSE INJURY OR DEATH.
Regulatory disposal information
European Waste Code : 13 02 XX
waste engine, gear and lubricating oils
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.