Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 412-720-6 | CAS number: 156653-67-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Short-term toxicity to fish
Administrative data
- Endpoint:
- short-term toxicity to fish
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 05 April 1993 to 23 April 1993
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Study conducted to EU & OECD test guidance in compliance with GLP
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 1 993
- Report date:
- 1993
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.1 (Acute Toxicity for Fish)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 203 (Fish, Acute Toxicity Test)
- Deviations:
- no
- GLP compliance:
- yes
Test material
- Details on test material:
- See below
Constituent 1
- Specific details on test material used for the study:
- Details on properties of test surrogate or analogue material (migrated information):
Not applicable.
Sampling and analysis
- Analytical monitoring:
- yes
- Details on sampling:
- Test concentrations: 0 / 100 / 220 mg/l
In order to determine the substance concentration, water samples were taken from the middle of the test chamber by pipetting approx. 20 ml into a screw-neck glass bottle at study start, and after 48 and 96 hours.
Test solutions
- Vehicle:
- no
- Details on test solutions:
- The test substance was weighed in a beaker, water for dilution was added and the mixture homogenized using an Ultra-Turrax and Ultrasonic Bath and poured into the chamber under stirring with a glass rod. All tested concentrations were present as yellow solutions.
At study start the pH-value of the control group and the concentration groups (100 mg/l and 220 mg/l) were adjusted to pH 7.
All test batches were homogeneous. No particulate matter was observed.
In order to determine the substance concentration, water samples were taken from the middle of the test chamber by pipetting approx. 20 ml into a screw-neck glass bottle at study start, and after 48 and 96 hours. The following values were determined during the study:
Nominal - Measured
(mg/l) x (mg/l) %
220 193.3 87.9
All analytical values were in a range of ± 20 % of the nominal concentration.
Test organisms
- Test organisms (species):
- Danio rerio (previous name: Brachydanio rerio)
- Details on test organisms:
- Species: zebra fish Brachydanio rerio (HAMILTON-BUCHANAN)
Breeding station: Central Toxicology (Hoechst AG)
Date of hatching: 03/01/1992
Delivery date: 10/27/1992
The fish were kept for at least 14 days before the start of the study in water for dilution under the following conditions:
Temperature: 22 ± 1⁰C
Oxygen content: > 80 % of the saturation value
Duration of light period: 12 hours daily
Population density: < 1 g fish/L water
Feeding: twice daily ad libitum
Feed: Tetra Min, Tetra Werke', Helle (FRG]
The body length of 7 representative fish from each batch was measured.
Body length (cm)
Part of study Batch No. Date n Variation range x s
1 2/92/H2/L2 04/09/93 7 3.1 – 3.4 3.3 0.11
2 2/92/H2/L2 04/23/93 7 3.2 – 3.5 3.3 0.12
Total sample 14 3.1 – 3.5 3.3 0.12
Study design
- Test type:
- static
- Water media type:
- freshwater
- Limit test:
- yes
- Total exposure duration:
- 96 h
- Post exposure observation period:
- No post observation period
Test conditions
- Hardness:
- No data
- Test temperature:
- 21.0C - 22.8C
- pH:
- 7.0 - 7.7
- Dissolved oxygen:
- 6.5 - 9.5 mg/l
- Salinity:
- Not applicable.
- Nominal and measured concentrations:
- 100 and 220 mg/l
- Details on test conditions:
- Water for dilution
Reconstituted water, composition according to IS0/D1S 7346/1 was used as water for dilution.
Preparation was carried out in a unit consisting of two Hostalen14- lined steel vessels with a capacity of 1700 litres each.
The dilution water was prepared as described was aerated until oxygen saturation. The pH was measured before the use of each study batch and was 8.2-8.3.
Test conditions
The study was conducted in a static system. The test chambers, which were calibrated to 10 liters, were made of glass (length 30 cm, width 22 cm, height 24 cm) and stood in a water bath made of Hostalit ZR with a Plexiglas viewing panel. The temperature of the water bath was regulated by a thermostat to 22 ± 1 °C. The chambers were illuminated from above from 6.00 a.m. to 6.00 p.m. The test chambers were not aerated during the course of the study. - Reference substance (positive control):
- no
Results and discussion
Effect concentrations
- Duration:
- 96 h
- Dose descriptor:
- LC50
- Effect conc.:
- > 220 mg/L
- Conc. based on:
- test mat.
- Basis for effect:
- mortality (fish)
- Details on results:
- The fish showed changes in appearance and behaviour and swimming behaviour. No lethality occurred in the 220 mg/l group.
The LC50 after 96 hours therefore exceeds 220 mg/1. - Results with reference substance (positive control):
- Not applicable.
- Reported statistics and error estimates:
- All analytical values were in a range of ± 20 % of the nominal concentration.
Applicant's summary and conclusion
- Validity criteria fulfilled:
- yes
- Conclusions:
- In this 96-hour acute toxicity study of Reaktiv-Gelb F-66 923 FW in zebra fish (Brachydanio rerio) no lethality occurred in the 220 mg/l group.
The LC50 after 96 hours therefore exceeds 220 mg/l. - Executive summary:
The acute toxicity of Reaktiv-GelbF-66923 FW in fish was determined compliance with the requirements of EEC-Guideline79/831/EWG Appendix V Methods for the determination of ecotoxicity C.1. Acute toxicity on fish and the OECD-Guideline for testing of chemicals,203 Fish, Acute Toxicity Test.Study performed in compliance with the Principles of Good Laboratory Practice (GLP).
When testing the lethal effect of Reaktiv-Gelb F-66 923 FW in zebra fish (Brachydanio rerio) over a total of 96 hours according to the method described under section 4, no lethality occurred at 220 mg/1. The LC50 after 96 hours therefore exceeds 220 mg/1.
At study start the pH-values of the control group and the concentration groups (100 mg/1 and 220 mg/1) were adjusted to pH 7.
All tested concentrations were present as yellow solutions. All test batches were homogeneous. No particulate matter was observed.
The substance concentration was determined in the 220 mg/1 group. All values determined were in a range of + 20 % of the theoretical value.
The substance is not considered as harmful to fish.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.
Although ECHA is providing a lot of online material in your language, part of this page is only in English. More about ECHA’s multilingual practice.
Welcome to the ECHA website. This site is not fully supported in Internet Explorer 7 (and earlier versions). Please upgrade your Internet Explorer to a newer version.
the-echa-website-uses-cookies
find-out-more-on how-we-use-cookies