Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: scientifically acceptable, guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
EC Commission Directive 92/69/EEC ("Flammability(solids)"), annex A.10
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
3-cyano-3,5,5-trimethylcyclohexanone
EC Number:
411-490-4
EC Name:
3-cyano-3,5,5-trimethylcyclohexanone
Cas Number:
7027-11-4
Molecular formula:
C10 H15 N O
IUPAC Name:
3-cyano-3,5,5-trimethylcyclohexanone
Details on test material:
Name of test material (as cited in study report): Isophoronitrile
Analytical purity: pure

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

1. Preliminary test:

Burning time (200 mm test distance): Brief burning followed by rapid extinction.

Therefore, the preliminary screening test is negative.

2.) ----> not highly flammable

Applicant's summary and conclusion