Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove to fresh air. If still having difficulty breathing,
seek medical attention.
Emergency measure - Eyes: Flush with plenty of water. If irritation persists, seek
medical attention.
Emergency measure - Skin: flush with plenty of water.
Emergency measure - Ingestion: Seek medical advice immediately and show container or label
if available or consult Poison Information Centre.

Fire-fighting measures

Recommended extinguishing agent: All types of fire extinguishers are suitable.

Product arising from burning: Cox, Nox, HCl

Product determined by test: N

Protective equipment: Normal equipment when fighting chemical fires, including
oxygen mask, face protection and gloves.

Accidental release measures

Emergency measures in case of spillage: Avoid dusting. When necessary cover the spilled material
with foam in order to prevent displacement by wind or
draught. Sweep and shovel spill into plastic (lined) drums
and identify for chemical waste disposal via appropriate
corporate procedures.

Handling and storage

Handling: Aviod ingestion, inhalation and contact with the skin, eyes
and clothing. Use adequate ventilation and protective
clothing which include dust filter respirator, gloves and
goggles.

Storage: Store dry and in the dark at room temperatures.

Packaging of the substance and or preparation: Polyethylene bags in cardboard drums of 10 kg.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None known.

Chemical reaction with water: None known.

Dust explosion: None known.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: None

Industry - Possibility of neutralisation: not applicable

Industry - Possibility of destruction: controlled discharge: Not applicable


Controlled dumping of endproduct.

Industry - Possibility of destruction - incineration: A660


Only in special incinerator installation.
notifier.

Industry - Possibility of destruction - water purification: Not applicable

Public at large - Possibility of destruction: controlled discharge: Dumping of endproduct at licnsed landfill.