Registration Dossier

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Emergency measure - Inhalation: Symptoms as a result of inhalation are not likely to occur.
Emergency measure - Eyes: Flush immediately for at least 15 minutes with water.

Consult a physician.
Emergency measure - Skin: Wash immediately with plenty of water and soap; take off
immediately all contaminated clothing.

If symtoms persist seek medical attention.
Emergency measure - Ingestion: Give plenty of water to drink, induce vomiting.

Never give water to an unconscious person.

Fire-fighting measures

Recommended extinguishing agent: Carbon dioxyde, powder and alcohol resistent foam.

Product arising from burning: No tests carried out. On the basis of the composition
combustion in a therefore equipped installation will
generate water and carbon oxydes.

Product determined by test: N

Protective equipment: Fire fighting personnel must wear self contained breathing
apparatus with a positive pressure in the masks.

Accidental release measures

Emergency measures in case of spillage: According to standard procedures; embank, clean and possibly
empty watersystems.

Remove to a safe place.

Handling and storage

Handling: Use, if possible, in closed systems.

Apply, if necessary, room and local ventilation.

Standard personal protection, working clothes, neoprene
gloves and safety goggles against splashing of liquids.

Storage: Well closed in a warehouse under normal storage conditions.

Packaging of the substance and or preparation: Metal drums.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: No special dangers.

Chemical reaction with water: None.

Dust explosion: Not applicable.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: NA

Industry - Possibility of neutralisation: NA

Industry - Possibility of destruction: controlled discharge: NA

Industry - Possibility of destruction - incineration: NA

Industry - Possibility of destruction - water purification: NA

Industry - Possibility of destruction - other: NA

Public at large - Possibility of recovery/recycling: NA

Public at large - Possibility of neutralisation: NA

Public at large - Possibility of destruction: controlled discharge: NA

Public at large - Possibility of destruction - incineration: NA

Public at large - Possibility of destruction - water purification: NA

Public at large - Possibility of destruction - others: NA