Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
August 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Rheometer method

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
not specified
Principles of method if other than guideline:
The viscosity of the liquids is measured using a stress-controlled rotational rheometer (Paar-Physica UDS 200) fitted with a concentric cylinder system. Samples with low viscosities are measured with a double-gap (22.25/22.75; 23.5/24.0 mm) system whereas high viscosity liquids are measured with a single gap (12.5/13.56 mm) device. A few measurements are conducted over a shear rate range between 1 and 100 s-1. When the flow is Newtonian (i.e. the viscosity is independent of shear rate), which is usually the case for acrylate resins, the viscosity is returned at 20 or 100 s-1. The temperature is 23.0 °C and is controlled within 0.1°C.
GLP compliance:
no
Type of method:
other: Rheometry method

Test material

Constituent 1
Chemical structure
Reference substance name:
Not available
EC Number:
676-712-6
Cas Number:
68890-85-7
Molecular formula:
(C3H6O)n(C3H6O)n(C3H6O)nC6H14O3.xC3H4O2
IUPAC Name:
Not available
Details on test material:
Propylidynetrimethanol, propoxylated, esters with acrylic acid

Results and discussion

Viscosity
Temp.:
other: 23.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
0.256

Applicant's summary and conclusion

Conclusions:
The viscosity of Propylidynetrimethanol, propoxylated, esters with acrylic acid was measured via rotational rheometry and found to be 0.256 Pa.s at 23C.
Executive summary:

Propylidynetrimethanol, propoxylated, esters with acrylic acid has a viscosity of 0.256 Pa.s at 23C.