Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 940-284-1 | CAS number: 1591782-62-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation
- Remarks:
- other: in vitro
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2013-10-11 to 2013-12-03
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 013
- Report date:
- 2013
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- other: OECD Guideline for the Testing of Chemicals, number 437 “Bovine Corneal Opacity and Permeability Test Method for Identifying Ocular Corrosives and Severe Irritants” (adopted: 26 July 2013)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Bayerisches Landesamt für Gesundheit und dLebensmittelsicherheit, München, Germany)
Test material
- Reference substance name:
- D-Glucitol, 1-deoxy-1-(methylamino)-, N-[C8-10(even numbered) acyl] derivs.
- EC Number:
- 940-284-1
- Cas Number:
- 1591782-62-5
- Molecular formula:
- C15H31NO6 C17H35NO6
- IUPAC Name:
- D-Glucitol, 1-deoxy-1-(methylamino)-, N-[C8-10(even numbered) acyl] derivs.
- Test material form:
- other: solid
- Details on test material:
- Chemical Name: D-Glucitol, 1-deoxy-1-(methylamino)-, N-C8-10 acyl derivs.
CAS No.: 85316-98-9 and 85261-20-7 (related to main C-chain lengths of the active material)
Physical State: solid, powder
Colour: colourless
Molecular Weight: 321.42 – 349.47 g/mol
pH: 8-10 (20°C, 10 g/l)
Storage Conditions: room temperature
Safety Precautions: The routine hygienic procedures were sufficient to assure personnel health and safety.
Constituent 1
Test system
- Vehicle:
- physiological saline
- Amount / concentration applied:
- The test item was diluted with physiological saline 0.9% NaCl to gain a 20% concentration.
- Duration of treatment / exposure:
- 750 µL of the test item preparation or the control substance was introduced into the anterior chamber (closed-chamber method). After 4 hours ± 5 minutes incubation at 32 +/- 1 °C either the test substance or the control substance was removed and the epithelium washed at least three times with MEM (containing phenol red).
- Details on study design:
- Test System
Preparation of the Corneas:
The assay uses isolated corneas obtained as a by-product from an abattoir from freshly slaughtered animals (from Attenberger Fleisch GmbH & Co. KG).
On the test day, fresh eyes were collected from the slautherhouse and were transported in HBSS containing Pen/Strep on ice to the laboratories.
Immediately after arrival of the eyes, cornea preparation was initiated.
The eyes were carefully examined for defects and any defective eyes were discarded.
The tissue surrounding the eyeball was carefully pulled away and the cornea was excised leaving a 2 to 3 mm rim of sclera. The isolated corneas were stored in a petri dish containing HBSS. Before the corneas were mounted in corneal holders (MC2, Clermont, France) with the endothelial side against the O-ring of the posterior chamber, they had been visually examined for defects and any defective cornea had been discarded. The anterior
chamber was then positioned on top of the cornea and tightened with screws. The chambers of the corneal holder were then filled with RPMI (without phenol red) containing 1% FBS and 2 mM L-glutamine (complete RPMI). The posterior chamber was always filled first. The corneas were incubated for one hour at 32 +/- 1 °C in a water bath.
Calibration of the Opacitometer:
The opacitometer had been switched on 15 min before the calibration procedure was started. Empty cornea holders were placed into the
opacitometer and the readout was adjusted to zero using the “BAL”-turning knob. For calibration the polyester foil no. 1 was introduced into the test chamber and the readout was adjusted to 75 using the “CAL”-turning knob. To test the linearity of the measurement, two additional calibration foils, polyester foil no. 2 and polyester foil no. 3, were measured. For these, the opacitometer was supposed to display 150 and 225, respectively (± 3%).
If this had not been the case, the calibration procedure would have had to be repeated. The calibration procedure was performed before each test
and was documented in the raw data.
Treatment of the Corneas:
After the equilibration period, the medium was removed from both chambers and replaced with fresh Complete RPMI. An initial opacity measurement was performed on each of the corneas using an opacitometer (MC2, Clermont, France). Three corneas with opacity readings approximately
equivalent to the median opacity of all corneas were selected as negative-control corneas. The opacity of each cornea was read against an air-filled
chamber and recorded. Corneas that have an initial opacity reading above 7 units were not dosed. The medium was removed from the anterior
chamber and replaced with the test item or control.
750 microL of the test item preparation or the control substance was introduced into the anterior chamber (closed-chamber method).
After 4 hours ± 5 minutes incubation at 32 +/- 1 °C either the test substance or the control substance was removed and the epithelium washed
at least three times with MEM (containing phenol red). Once the medium was free of test substance, the cornea was finally rinsed with complete RPMI (without phenol red). The anterior chamber was refilled with complete RPMI and an opacity measurement was performed.
After the opacity measurement the medium was removed from both chambers of the holder. The posterior chamber was refilled with fresh complete RPMI. 1 mL of a 5 mg/mL sodium fluorescein solution was added to the anterior chamber and the corneas were incubated for 90 minutes
at 32 +/- 1 °C. Then the medium from the posterior chamber was removed and its optical density at 490 nm (OD490) was determined,
using a spectrophotometer.
Test Groups:
3 corneas for the test item
3 corneas as negative controls treated with physiological saline 0.9% NaCl
3 corneas as positive control treated with imidazole 20% in physiological saline 0.9% NaCl
The BCOP assay is considered to be valid if the in vitro score obtained with the positive control falls within the two standard deviations of the current historical mean.
Evaluation of Results:
The change in opacity for each cornea was calculated by subtracting the initial opacity reading from the final opacity reading. These values were
corrected by subtracting from each the average change in opacity observed for the negative-control corneas. The mean opacity value for each
treatment was calculated by averaging the corrected opacity values of each cornea for a given treatment.
The mean OD490 for the blank wells were calculated. The mean blank OD490 was subtracted from the OD490 of each well (corrected OD490).
Any dilutions that were made to bring the OD490 values into the linear range of the spectrophotometer (OD490 should be less than 1.500), were
taken into account by multiplying the OD490 value of the dilution by the dilution factor. The final-corrected OD490 of the test article and the positive
control were calculated by subtracting the average corrected OD490 of the negative control corneas from the corrected OD490 value of each
treated cornea:
Final-corrected OD490 = (OD490 – mean blank OD490) – average-corrected negative control OD490
The mean OD490 value of each treatment group was calculated by averaging the final corrected OD490 values of the treated corneas
for that treatment condition.
The following formula was used to determine the in vitro score:
In vitro score = mean opacity value + (15 x mean OD490 value)
Results and discussion
In vivo
Results
- Irritation parameter:
- other: in vitro irritation score (IVIS)
- Remarks on result:
- other: According to Article 13 of the REACH Regulation (EC) 1907/2006, information on the endpoint `eye irritation` has been generated using OECD TG 437 `BCOP for identifying ocular corrosives and severe irritants`. Thus no standard scores are given.
- Irritant / corrosive response data:
- The following mean in vitro irritation score was calculated:
130.97
The in vitro irritation score obtained with the positive control fell within the two standard deviations of the current historical mean and therefore this assay is considered to be valid.
Applicant's summary and conclusion
- Interpretation of results:
- other: severe irritant
- Remarks:
- Criteria used for interpretation of results: other: OECD
- Conclusions:
- Based on the results of this in vitro study and under the given conditions the test item C8/10-Glucamide AC93/13 is considered to be a
severe irritant to the eyes. - Executive summary:
- Summary
Results
The eye irritancy potential of Glucamide 810 was investigated in the bovine corneal opacity and permeability assay.
Preparation of the test item: suspended with physiological saline 0.9% NaCl to gain a 20% concentration
Mean in vitro irritation score: 130.97
The in vitro irritation score obtained with the positive control fell within the two standard deviations of the current historical mean and therefore this assay is considered to be valid.
Conclusion
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.