Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

The manufacturing/use of the registered substance fulfils strictly controlled conditions. Therefore, no exposure of man or the environment is expected. In the case of accidental exposure, the following measures should be taken (as reported by the Safety Data Sheet):

Eye contact - in case of contact with eyes rinse thoroughly with plenty of water and get medical advice

Skin contact - remove immediately contaminated clothes, wash affected skin with plenty of water

Inhalation - in case of inhalation remove to fresh air and seek medical aid

Ingestion - consult physician

Fire-fighting measures

Suitable extinguishing media - water spray jet, dry powder, foam, carbon dioxide

Flash point (liquid) not applicable

Specific hazards - severe dust explosion hazard

Protection of fire-fighters - use self-contained breathing apparatus

Special method of fire-fighting - cool endangered containers with water spray

Accidental release measures

The manufacturing/use of the registered substance fulfils strictly controlled conditions. Therefore, no exposure of man or the environment is expected. In the case of accidental exposure, the following measures should be taken (as reported by the Safety Data Sheet):

Personal precautions - ensure adequate ventilation

Environmental protection - avoid release to the environment

Methods for cleaning up:

- Scoop or shovel spilled material into a suitable labeled open head drum

- Secure the drum cover and move the container to a safe holding area

- Clean spill area thoroughly

- Collect wash with a noncombustible absorbent material and transfer to labeled container for treatment and disposal.

- Check area for residual material and repeat clean up if detected

Handling and storage

Technical measures:

- processing in closed systems, superposed by inert gas (e.g. nitrogen)

- local exhaust ventilation necessary

- take precautionary measures against electrostatic charging

- avoid dust formation; very high dust explosion hazard

- low minimum ignition energy

Suitable materials - stainless steel, polyethylene

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
not classified by transport regulations, proper shipping name non-regulated
Shippingopen allclose all
Labels:
not classified by transport regulations, proper shipping name non-regulated
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
not classified by transport regulations, proper shipping name non-regulated
Shippingopen allclose all
Labels:
not classified by transport regulations, proper shipping name non-regulated
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
not classified by transport regulations, proper shipping name non-regulated
Shipping information
Proper shipping name and description:
not classified by transport regulations, proper shipping name non-regulated
Chemical name:
not classified by transport regulations, proper shipping name non-regulated
Labels:
not classified by transport regulations, proper shipping name non-regulated
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
not classified by transport regulations, proper shipping name non-regulated
Shipping information
Proper shipping name and description:
not classified by transport regulations, proper shipping name non-regulated
Chemical name:
not classified by transport regulations, proper shipping name non-regulated
Labels:
not classified by transport regulations, proper shipping name non-regulated
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Engineering Measures:

Technical measures

- processing in closed systems, superposed by inert gas (e.g.nitrogen)

- local exhaust ventilation necessary

- take precautionary measures against electrostatic charging

- avoid dust formation; very high dust explosion hazard

- low minimum ignition energy

Suitable materials:

- stainless steel, polyethylene

Monitoring:

Threshold value (Roche) air - IOEL (Internal Occupational Exposure Limit): 0.5 mg/m3

Personal protective equipment:

Respiratory protection:

- Respiratory protection is recommended as a precaution to minimze exposure. Effective engineering controls are considered to be the primary means to control worker exposure. Respiratory protection should not substitute for feasible engineering controls.

- Respiratory protection is recommended for dusty operations.

- Use of a negative pressure air purifying, half face respirator with a toxic/dust/mist/fume high efficiency filter in the laboratory or a supplied-air full facepiece respirator or supplied-air hood for production operations is recommended.

Hand protection: - protective gloves

Eye protection: - safety glasses

Body protection: - protective clothing

Stability and reactivity

Stability - stable under normal conditions

Conditions to avoid - temperatures above 80 °C

Materials to avoid - strong oxidizing agents, strong acids, strong bases

Hazardous decomposition products:

- carbon monoxide

- carbon dioxide

- hydrogen chloride

- oxides of nitrogen clothing

Disposal considerations

Waste from residues:

- incinerate in qualified installation with flue gas scrubbing

- observe local/national regulations regarding waste disposal

Contaminated packaging:

- Empty containers must be triple rinsed prior to disposal, recycling or reuse.

RCRA waste:

- not regulated under RCRA