Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05.06.2012 - 15.06.2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Justification for type of information:
Data is from experimental study report
Qualifier:
according to guideline
Guideline:
other: as mentioned below
Principles of method if other than guideline:
Temperature at which a substance catches fire without the help of a source of ignition such as on exposure to air
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Key result
Atm. press.:
970 hPa
Remarks on result:
other: Test substance did not catch fire on being exposed to air at room temperature of 32 degC.
Conclusions:
Test substance did not catch fire on being exposed to air at room temperature of 32 degC and atmospheric pressure of 970 hPa. This indicates that it is not auto-flammable.
Executive summary:

Test substance did not catch fire on being exposed to air at room temperature of 32 degC and atmospheric pressure of 970 hPa. This indicates that it is not auto-flammable.

Description of key information

Test substance did not catch fire on being exposed to air at room temperature of 32 degC and atmospheric pressure of 970 hPa. This indicates that it is not auto-flammable.

Key value for chemical safety assessment

Additional information

Test substance did not catch fire on being exposed to air at room temperature of 32 degC and atmospheric pressure of 970 hPa. This indicates that it is not auto-flammable.