Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July 19,1985
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N
Remarks:
No reaction at 36 kg
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Remarks:
10 kg of weight, 6 attemos, no response
Key result
Parameter:
thermal sensitivity - Koenen test: limiting diameter (mm)
Number of fragments:
0
Remarks on result:
not thermal sensitive if heated under defined confinement
Remarks:
no explosion for any of three tests with 2 and 6 mm of diameter hole

The friction apparatus showed no reaction at 36 kg.

The hammer test: 10 kg of weight, 6 attempts, no response.

Thermal sensitivity: no explosion for any of three tests with 2 and 6 mm of diameter hole

Interpretation of results:
non explosive
Conclusions:
The test item is not explosive in accordance with EU method A.14
Executive summary:

The test substance was tested by EU method A.14. The substance result not explosive

Description of key information

Non explosive when tested for relevant safety indicators.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

The test substance was tested by EU method A.14. The substance result not explosive

Justification for classification or non-classification