Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Testing was conducted between 03 April 2007 and 24 April 2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP and in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not effect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: 92/69/EEC, A16
GLP compliance:
yes (incl. QA statement)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Sponsor's identification: C-Y9
Description : yellow powder
Lot number : MB-1
Date received : 06 March 2007
Storage conditions: room temperature in the dark over silica gel.

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
> 400 °C
Remarks on result:
other: Pressure inot indicated.
Relative self-ignition temperature (solids)
Relative self-ignition temperature:
> 400 °C
Remarks on result:
other: Pressure inot indicated.

Any other information on results incl. tables

Observations after the test:

The cube contained black charred remains.

Applicant's summary and conclusion

Conclusions:
The test material has been determined not to have a relative self-ignition temperature below 400°C.
Executive summary:

Method:

The test material was heated in an oven and the relative self ignition temperature determined. Testing was conducted using Method A16 of Commission Directive 92/69/EEC (which constitutes Annex V of Council Directive 67/548/EEC).

Conclusion:

The test material has been determined not to have a relative self-ignition temperature below 400°C.