Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 Sep 2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
1992
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Atm. press.:
1 012.4 hPa
Remarks on result:
no flash point - measurement carried out until boiling temperature

Validity criteria for the measurement of the flash point according to 92/69/EWG A.5:


The study was performed according to EU method A.5. No flash point could be measured - the measurement was carried out until boiling temperature. Thus, the validity criteria cannot be applied, here. 

Interpretation of results:
GHS criteria not met
Conclusions:
No flash point was observed until the boiling of the test item of approximately 205 °C.
Executive summary:

No flash point was observed until the boiling of the test item of approximately 205 °C.

Description of key information

No flash point was observed until the boiling of the test item of approximately 205 °C.

Key value for chemical safety assessment

Additional information