Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10/11/2018 – 10/18/2018
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
27 July 1995
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Version / remarks:
30 May 2008
GLP compliance:
no
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Test material form:
solid: particulate/powder

Results and discussion

Melting / freezing point
Key result
Decomposition:
yes
Decomp. temp.:
ca. 205 °C

Applicant's summary and conclusion

Conclusions:
No melting point was determined prior to the exothermic decomposition of the test item, starting at around 205 °C.