Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
partition coefficient
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model, but not (completely) falling into its applicability domain, with adequate and reliable documentation / justification
Remarks:
The substance is not fully compliant with the applicability domain of the model. However, this calculation is used in a weight of evidence approach, in accordance to the REACh Regulation (EC) No 1907/2006, Annex XI General rules for adaptation of the standard testing regime set out in Annexes VII to X, 1.2. It is adequately documented and justified. For more detail see field `overall remarks, attachments´.
Justification for type of information:
1. SOFTWARE
VEGA version 1.1.3

2. MODEL (incl. version number)
Meylan/Kowwin v. 1.1.4

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
See “Test material information”

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See attached information on the model provided by the developer. Further information on the OECD criteria as outlined by the applicant is provided below under "Any other information of materials and methods incl. tables"

5. APPLICABILITY DOMAIN
See attached information and information as provided in "Any other information on results incl. tables".

6. ADEQUACY OF THE RESULT
See assessment of adequacy as outlined in the "Overall remarks, attachments" section.
Qualifier:
according to guideline
Guideline:
other: REACH Guidance on QSARs R.6
Principles of method if other than guideline:
- Software tool(s) used including version: Vega v1.1.3
- Model(s) used: BCF Meylan Model version 1.0.3
Full reference and details of the used formulas can be found in:
Meylan W.M., Howard P.H., Boethling R.S. et al. Improved Method for Estimating Bioconcentration / Bioaccumulation Factor from Octanol/Water Partition Coefficient. 1999, Environ. Toxicol. Chem. 18(4): 664-672
- Model description: see field 'Justification for non-standard information', 'Attached justification' and 'any other information on Material and methods'
- Justification of QSAR prediction: see field 'Justification for type of information', 'Attached justification' and/or 'overall remarks'
GLP compliance:
no
Type of method:
other: QSAR
Partition coefficient type:
octanol-water
Type:
log Pow
Partition coefficient:
> 10
Remarks on result:
other: QSAR result, no information on temperature and pH available
Details on results:
Constituent 1, Mw = 1426.42 g/mol, log Pow = 40.14
Constituent 2, Mw = 1398.37 g/mol, log Pow = 39.15
Constituent 3, Mw = 1370.31 g/mol, log Pow = 38.17

For detailed information on the results please refer to the attached report.

Endpoint:
partition coefficient
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model, but not (completely) falling into its applicability domain, with adequate and reliable documentation / justification
Remarks:
The substance is not fully compliant with the applicability domain of the model. However, this calculation is used in a weight of evidence approach, in accordance to the REACh Regulation (EC) No 1907/2006, Annex XI General rules for adaptation of the standard testing regime set out in Annexes VII to X, 1.2. It is adequately documented and justified: the overall internal quality check in VEGA v1.1.3 indicates that the prediction is reliable with a Klimisch score of 2.
Justification for type of information:
1. SOFTWARE
VEGA version 1.1.3

2. MODEL (incl. version number)
ALogP Model v. 1.0.0

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
See “Test material information”

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See attached information on the model provided by the developer. Further information on the OECD criteria as outlined by the applicant is provided below under "Any other information of materials and methods incl. tables"

5. APPLICABILITY DOMAIN
See attached information and information as provided in "Any other information on results incl. tables".

6. ADEQUACY OF THE RESULT
See assessment of adequacy as outlined in the "Overall remarks, attachments" section.
Qualifier:
according to guideline
Guideline:
other: REACH Guidance on QSARs R.6
Principles of method if other than guideline:
- Software tool(s) used including version: VEGA v1.1.3
- Model(s) used: ALogP Model version 1.0.0
The model is based on the Ghose-Crippen-Viswanadhan LogP (ALogP) and consists of a regression equation based on the hydrophobicity contribution of 120 atom types as described in: A.K. Ghose and G.M. Crippen, J. Comput. Chem. 1986, 7, 565-577; V.N. Viswanadhan et al., J. Comput. Chem. 1993, 14, 1019-1026; A.K. Ghose, V.N. Viswanadhan, J.J. Wendoloski, J. Phys. Chem. A 1998, 102, 3762-3772. For the purpose of applicability domain assessment, the training set of the Meylan LogP model (9,961 compounds) has been considered, setting all molecules as belonging to the test set.
- Model description: see field 'Justification for type of information', 'Attached justification' and 'any other information on Material and methods'
- Justification of QSAR prediction: see field 'Justification for type of information', 'Attached justification' and/or 'overall remarks'
GLP compliance:
no
Type of method:
other: QSAR
Partition coefficient type:
octanol-water
Type:
log Pow
Partition coefficient:
> 10
Remarks on result:
other: QSAR result, no information on temperature and pH available
Details on results:
Constituent 1, Mw = 1426.42 g/mol, log Pow = 36.69
Constituent 2, Mw = 1398.37 g/mol, log Pow = 35.78
Constituent 3, Mw = 1370.31 g/mol, log Pow = 34.87

For detailed information on the results please refer to the attached report.

Description of key information

Log Pow > 10 (QSAR, VEGA version 1.1.3 - two models: Meylan/Kowwin version 1.1.4, ALogP version 1.0.0)

Key value for chemical safety assessment

Additional information

The log Pow of the substance Fatty acids C18-C22 (even numbered), tetraesters with pentaerythritol was determined by QSAR calculation with VEGA 1.1.3. for the three constituents of this UVCB substance.

Due to the fact that this substance's constituents are long chain hydrocarbons which exceed the applicability domain of VEGA the value for log Pow is reported with restrictions.Therefore the partition coefficient of the substance is deduced to be > 10.