Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
Official Journal of the European Union L 142 of 31 May 2008
GLP compliance:
yes
Specific details on test material used for the study:
Chemical name: 2-hydroxyethanesulfonic acid compound with 4,4’-[hexane-1,6-diylbis(oxy)]bis[benzenecarboxamidine] (2:1)
Batch/Lot number: 42964
Expiry (Retest) date: 31 January 2019
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
2 min

In the preliminary test the test item could not be ignited. The test item melted and the melted part of test item flamed for a few second. Based on the results of the preliminary test, no main test was performed.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item could not be ignited. Therefore, the substance is considered not to be highly flammable.

Executive summary:

Two parallel flammability tests were performed. The tests were negative.

The test item is not highly flammable in the conditions of this test.

Description of key information

The test item could not be ignited. Therefore, the substance is considered not to be highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

Two parallel flammability tests were performed. The tests were negative.

The test item is not highly flammable in the conditions of this test.