Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Remarks:
Flash point is also relevant for solids with low melting point.
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Justification for type of information:
The flash-point of the test substance was determined by Cleveland open cup method according to ASTM D92. Since the measured flash-point is far above the classification limit the open-cup method is accepted.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM D92 (Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester)
GLP compliance:
no
Type of method:
open cup
Flash point apparatus:
other: Cleveland Open Cup

Test material

Constituent 1
Chemical structure
Reference substance name:
Fatty acids, vegetable-oil, polymd., esters with 1,2-hexadecanediol
Cas Number:
68910-99-6
Molecular formula:
Not applicable (i.e., UVCB substance)
IUPAC Name:
Fatty acids, vegetable-oil, polymd., esters with 1,2-hexadecanediol

Results and discussion

Flash pointopen allclose all
Flash point:
340 °F
Atm. press.:
ca. 1 013 hPa
Key result
Flash point:
171.1 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: Flash point in °C calculated from the value in °F reported in the certificate.

Any other information on results incl. tables

Pressure ca. 1013 hPa assumed based on open cup method (value not reported in the certificate).

Applicant's summary and conclusion