Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)
Remarks:
certificate no.: 17/2017/DPL
Test procedure:
burning rate test: preliminary screening test
Burning time:
0 s
Remarks on result:
other: After the ignition the sample charred only in the place of applying the flame of burner. The flame did not propagate. Time of applying the flame of burner: 30, 60, 120 s.

Results of preliminary test

Test number

Time of burning [s]

Comments

Test-1

-

After the ignition the sample charred only in the place of applying the flame of burner. The flame did not propagate. Time of applying the flame of burner: 30, 60, 120 s.

Result: NEGATIVE

Test-2

-

Test-3

-

Interpretation of results:
not classified based on GHS criteria
Conclusions:
DTPA-FeK (FeDTPA K) is not highly flammable in accordance with test A.10. criteria.
Executive summary:

Flammability (solids) was performed for DTPA-FeK according to method A.10 Flammability (solids). The preliminary screening test was made to determine if, on ignition by a gas flame, propagation by burning with flame or smouldering occurs.

Since the result was negative, it was not necessary to go to the next stage of determination. DTPA-FeK (FeDTPA K) is not highly flammable in accordance with test A.10. criteria.

Description of key information

DTPA-FeK (FeDTPA K)  is not highly flammable in accordance with test A.10. criteria.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The target substance DTPA-FeK (FeDTPA K) is not highly flammable in accordance with test A.10. criteria and does not need to be classified and labeling acc. Regulation 1272/2008.