Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Version / remarks:
Jan 2001
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
Version / remarks:
May 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method
Media:
soil/sewage sludge
Radiolabelling:
no
Test temperature:
25 °C (column temperature)
Details on study design: HPLC method:
EQUIPMENT
- Apparatus:
- Type: Merck-Hitachi LaChrom HPLC system
- Type, material and dimension of analytical column: LiChrospher 100 CN 250 × 4.6 mm, 5 µm
- Detection system: UV set at 230 and 245 nm

MOBILE PHASES
- Type: Acetonitrile : ultrpure water 6:4, isocratic, 1 ml/min
- Solutes for dissolving test and reference substances: stock solutions were prepared in methanol (test substance) and acetonitrile (reference substances), respectively and diluted with the HPLC mobile phase

DETERMINATION OF DEAD TIME
- Method: by inert substance which is not retained by the column: sodium nitrate (RT = 1.56 min)

REFERENCE SUBSTANCES
- Identity (known log Koc): acetanilide (1.25), methyl benzoate (1.80), linuron (2.59), naphthalene (2.75), fenthion (3.31), alpha-Endosulfan (4.09), DDT (5.63)

DETERMINATION OF RETENTION TIMES
- Quantity of test substance introduced in the column: about 1 µg
- Quantity of reference substances: approx. 0.1 µg
- Intervals of calibration: three series of the reference solutions and the test item solution were measured alternately, with two replicate injections

REPETITIONS
- Number of determinations: two

EVALUATION
- Determination of the log Koc value: A calibration plot of log k versus log Koc was prepared for the reference standards. The calibration equation was determined by linear regression using the least squares method. The capacity factors k were calculated from the dead time and retention times of the reference substances. The log k data of the reference substances were plotted against their log Koc values.
Key result
Type:
log Koc
Value:
>= 3.04 - <= 4.63 dimensionless
Temp.:
25 °C
Key result
Type:
Koc
Value:
>= 1 096 - <= 42 658 dimensionless
Temp.:
25 °C
Details on results (HPLC method):
- Retention times of reference substances used for calibration: acetanilide: 3.68, methyl benzoate: 4.07, linuron: 4.45, naphthalene: 4.79, fenthion: 5.06, alpha-endosulphan: 5.57, DDT: 6.51 minutes
- Details of fitted regression line (log k' vs. log Koc): log k' = 0.082 x log Koc + 0.065 (Rsq = 0.968)
- Graph of regression line attached ("Tables & Figures - Koc.pdf")
- Average retention data for test substance: Peak 1: 4.83 minutes, Peak 2: 5.27 minutes, Peak 3: 5.97 minutes (see attached document "Tables & Figures - Koc.pdf")
Validity criteria fulfilled:
not applicable

Description of key information

Log Koc at 25 °C: 3.04 - 4.63 (HPLC method; OECD 121, EU C.19)

Key value for chemical safety assessment

Additional information

Koc at 25 °C: 1096 - 42658 (Log Koc 3.04 - 4.63)